MAX PRO-SERIES Communication/Configuration Specifications (continued)

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901

12

?ID<CR>

?TRIGSTAT<CR>

?OUTLETSTAT<CR>

?POWERSTAT<CR>

?VOLTAGE<CR>

?CURRENT<CR>

?HELP<CR>

Request that the unit identify itself.

Request the on/off status of the front panel
button and input trigger.

Request the on/off status of the
outlet banks and output trigger.

Request the status of the input voltage.

Request the line voltage.

Request the input current draw.

Request a list of all commands
and queries.

2.1

2.2

2.3

2.4

2.5

2.6

2.7

$PANAMAX<CR>

$MAX 74/7500-PRO<CR>

$FIRMWARE revision<CR>

if front panel button is ON, $BUTTON = ON<CR>

if front panel button is OFF, $BUTTON = OFF<CR>

if input trigger is ON, $TRIGIN = ON<CR>

if trigger input is OFF, $TRIGIN = OFF<CR>

$BANK1 = status<CR>

$BANK2 = status<CR>

$BANK3 = status<CR>

$BANK4 = status<CR>

$HC1 = status<CR>

$HC2 = status<CR>

$TRIGOUT = status<CR>

status = { ON, OFF }

if input voltage is within limits, $PWR = NORMAL<CR>

during overvoltage, $PWR = OVERVOLTAGE<CR>

during undervoltage, $PWR = UNDERVOLTAGE<CR>

during recovery, $PWR = RECOVERY<CR>

If 140V > Vin > 90: $VOLTAGE = xxx<CR>

where xxx is the input line voltage expressed in decimal format. If the
voltage is less than 100, the hundreds digit is represented with a 0.
For example, a line voltage of 92VAC would be expressed as:

$VOLTAGE = 092<CR>

If Vin > 140V: $VOLTAGE = OVERVOLTAGE

If Vin < 90V: $VOLTAGE = UNDERVOLTAGE

$CURRENT = xxx<CR>

where xxx is the input current expressed in decimal format. If the cur-
rent is less than 10, the tens digit is represented with a 0. For example,
a current of 3.3A would be expressed as:

$CURRENT = 03.3<CR>

Transmit a listing of all commands and queries.

QUERIES

Query Description Response