Alarms

The DSU/CSU can be attached, either locally or

remotely, to an ASCII terminal or printer to display or
print alarm messages. Alarms can also be displayed on a
PC that is using a terminal emulation package.

You can route these alarms to the MODEM port, the

COM port, or both.

Each alarm message contains a customer identification

to indicate which remote DSU/CSU is reporting an alarm.
For information about customer identification, refer to the

Displaying Unit Identity

section in Chapter 3, Operation.

Possible alarm messages are as follows:

Continuous Loss Of Signal detected at the
Network
Interface.

Alarm Cleared. Loss Of Signal condition at the
Network Interface
.

Continuous Out Of Frame condition detected at
the Network Interface
.

Alarm Cleared. Out Of Frame condition at the
Network Interface
.

Alarm Indication Signal received at the Network
Interface
.

Alarm Cleared. Alarm Indication Signal at the
Network Interface
.

An Excessive Error Rate has been detected at
the Network Interface
.

Alarm Cleared. An Excessive Error Rate at the
Network Interface
.

Yellow Alarm signal received at the Network
Interface
.

Alarm Cleared. Yellow Alarm signal at the
Network Interface
.

Continuous Out Of Frame condition detected at
synchronous data port 1
.

Alarm Cleared. Out Of Frame condition at
synchronous data port 1
.

An Excessive Error Rate has been detected at
synchronous data port 1
.

Alarm Cleared. An Excessive Error Rate at
synchronous data port 1
.

If two alarm conditions are detected at once, the higher

priority alarm is reported. However, if an even higher
priority alarm is detected before the first alarm is cleared,
the later alarm is not reported. (The alarms listed above
are in priority order with the highest priority listed first.)

Alarms remain active until the alarm condition is

cleared. Also, an alarm clear message is only sent when
there are no other alarms active.

For information about alarm configuration options,

refer to the

Alarm Configuration Options

section in

Appendix C, Configuration Options.

For troubleshooting information, refer to the

Troubleshooting

section.

Troubleshooting

The DSU/CSU is designed to provide you with

trouble-free service. However, Table 4-4 gives you some
direction if a problem occurs.

For problems other than those listed in the table, please

contact your service representative.

Table 4-4

(1 of 2)

Troubleshooting

Symptom

Possible Cause

Solutions

No power

1. The power module is not securely attached.

2. The wall receptacle has no power.

1. Check the power module attachment.

2. Check the wall receptacle power by plugging

in some equipment that is known to be
working.

Power-Up
Self-Test fails

The DSU/CSU has detected an internal hardware
failure.

Contact your service representative.