Important instructions before installation, Performance table – Pentair MYERS S33 User Manual

Page 3

Advertising
background image

P.

2

23833A587

Bag #18812A108

P.

3

23833A587

Bag #18812A108

Warranty void if product modified, drilled, painted,
or altered in any way; if used to pump hot water,
or to pump liquids other than water (such as but
not limited to chemicals, fertilizers, flammable

liquids, herbicides, mud, tar, cement, wood chips); or
otherwise abused.
WARNING, risk of electric shock – This pump is supplied
with a grounding conductor and grounding-type attachment
plug. To reduce the risk of electric shock, be certain that it
is connected only to a properly grounded, grounding-type
receptacle. This pump has not been investigated for use in
swimming pool areas. DO NOT WORK ON PUMP UNTIL POWER
IS UNPLUGGED. DO NOT cut off ground pin or use an adapter
fitting. DO NOT use an extension cord. The pump power
cord should be connected to a separately fused, grounded
115 volt line with a capacity of 15 amps. NEVER touch the
pump when it is connected to electrical power.
1. Before installing or servicing your pump, BE CERTAIN
pump power source is disconnected.
2. Installation and electrical wiring must adhere to state
and local codes and must be complete before priming pump.
Check appropriate community agencies, or contact local
electrical and pump professionals.
3. CALL AN ELECTRICIAN WHEN IN DOUBT. Pump should be
connected to a separate 15 amp circuit breaker or 15 amp fuse
block. Plugging into existing outlets may cause low voltage
at motor, causing blown fuses, tripping of motor overload,
or burned out motor.
4. A permanent ground connection from pump to the
grounding bar at the service panel is mandatory. Myers sump
pumps come with a grounding conductor and a grounding-
type attachment plug. Do not connect pump to a power
supply until permanently grounded. For maximum safety,
ground pump to a circuit equipped with a fault interrupter
device.

5. Voltage of power supply must match the voltage of the
pump. All Myers sump pumps are factory preset to
115V, 60Hz.
6. Before installing pump, clear sump basin of any water,
debris, or sediment.
WARNING: Sump basin must be vented in accordance

with local plumbing codes. Myers sump pumps are not

designed for and CANNOT be installed in locations

classified as hazardous in the National Electric Code,

ANSI/NFPA 70.
7.
The sump basin should be between 14" and 18" in
diameter for the S33A1, S33P-1, S33A1C, S33PC-1, S33M1C
and 12"–18" for the S33V1, S33V1C, S33PV1 made of plastic,
fiberglass, or concrete.
8. The following may cause severe damage to pump and will
void warranty:

• Using the pump without a check valve.

• Using an extension cord.
• Cutting off the ground pin or using an adapter fitting.
• Working on pump or switch while plugged in.
• Removing motor housing, unscrewing impeller, or
otherwise removing impeller seal.

Running the pump continuously.

• Pumping chemicals or corrosive liquids.
• Pumping gasoline or other flammable liquids.
PIPING
Plastic PVC pipe is shown in the illustrations, but drain
hose, galvanized steel or copper pipe may be used if desired.
All piping must be clean and free of all foreign matter to
prevent clogging. Use thread compound on all threaded
joints unless specified otherwise.
9. Do not open pump housing to attempt repair–this will
cause a severe shock hazard.
10. Any finished basement or living area should be equipped
with a sump pump alarm to warn of a pump failure and
protect against water damage.
11. Cycle the pump at least once per month when regular
use isn’t occurring.
12. Always use a properly installed check valve with this
sump pump.

PUMP

MODEL

TOTAL HEAD (vertical pumping distance) IN FEET

S33

PERFORMANCE TABLE

(in gallons per minute)

6

33

8

30

10

29

12

27

14

25

16

23

18

17

20

15

22

12

22

2

A CHECK VALVE MUST BE USED IN THE DISCHARGE LINE FOR ALL PUMPS. A shut-off valve should be used. Always install
check valve with arrow on body in direction of flow.

PUMP MOTOR
NEVER REMOVE MOTOR HOUSING OR UNSCREW PUMP IMPELLER. Warranty on pump is void if motor housing, impeller or seal have
been removed. Any repair on motor must be done by an authorized Myers service center.

IMPORTANT INSTRUCTIONS BEFORE INSTALLATION

Failure to follow these instructions may cause serious bodily injury and/or property damage.