Shooting

45

3D FINE function

As the left and right lenses are linked, you
normally do not need to adjust them.
If you wish to perform fine adjustments between
the two lenses, the 3D FINE function allows you
to adjust the vertical position of the images, focus
and iris.

EXEC

MENU

AUDIO MON/ADV

PUSH

ENTER

1

Perform zoom adjustment (Page 34),

focus adjustment (Page 36) or brightness

adjustment (Page 37).

2

Press the EXEC button.

The fine adjustment screen is displayed.

3

Adjust the vertical position of the images,

focus and iris finely.

Vertical position of the images

(VERTICAL): Tilt the Operation lever in the

directions. The image from the right lens

moves upwards by tilting it in the direction,
and downwards by tilting it in the direction.

This product is preadjusted at the factory
to minimize vertical misalignment.

*

1

The

specification for vertical misalignment is
1. % or less.

*

1

It is indicated in percentage of vertical
misalignment between the images from
the left and right lenses at the center
of the screen according to the effective
height of the screen, when measured
under the following conditions: the zoom
position at the maximum wide-angle
(Z00), the convergence point in the
center (C50), and shooting a subject at a
distance of 4.3 m.

Focus (FOCUS): Tilt the Operation lever in

the directions. The focal length for the
right lens is increased by tilting it in the
direction, and is reduced by tilting it in the
direction.

Iris (IRIS): Press the AUDIO MON/ADV

+/- buttons. The iris of the right lens is opened
by pressing the + button, and is closed by
pressing the – button.

4

Press the EXEC button to confirm the

adjustments.

When the adjustment screen of the 3D FINE
function is being displayed, only the MIX
button and the USER button with R-IMAGE
allocated operate. The other buttons are not
operative.
The fine adjustment value is cleared when
a zoom operation, focus adjustment, or
brightness adjustment using the IRIS/CONV.
dial is performed after the adjustment.
The fine adjustment value is cleared when
the power of the unit is turned off.

Advertising