Specifications................................................................................................................................................................................pg. 1
Important Safety Instructions / FCC Notice.......................................................................................................................................pg. 2
Key Features and Functions...........................................................................................................................................................pg. 3
Front and Back Panel Descriptions.................................................................................................................................................pg. 4
Installing Your MX5102 / UPS Operation.........................................................................................................................................pg. 5
Advanced Operation......................................................................................................................................................................pg. 6
Warranty Information.....................................................................................................................................................................pg. 7

In addition to this manual the box should contain the following:

1. UPS Unit

3. Coaxial Cables

2. Rack Mounting Kit

4. RJ-45 Network Cable

Before you begin unpacking inspect the MX5102 upon receipt.

MX5102 Specifications

AC Power

Line Voltage 120V, 60Hz
Total Current Capacity 12 A
Energy Dissipation 1800 Joules
Catastrophic Surge Circuit Yes
Thermal Fusing Yes

Overvoltage Shutoff, fast rise 150 ± 5 V
Overvoltage Shutoff, slow rise 132 ± 5 V
Undervoltage Shutoff 90 ± 5 V

EMI/RFI Noise Filtration
Bank 1 EMI Filtration 66dB Max, 100kHz-2MHz
Bank 2 EMI Filtration 66dB Max, 100kHz-2MHz

UPS Output

Voltage 120 ± 5% Simulated Sine Wave
Frequency 60 Hz ± 1%
UPS Output Capacity 600VA/360W @ 0.6pf
UPS Backup Time 3 minutes at full load
Transfer Time < 10ms

DC Trigger Input

Jacks 3.5mm (1/8”) mono mini-plug
Voltage and Polarity 3 - 18V DC, bidirectional
Current Requirement 4.6 mA @3V, 58 mA @18V

LAN Circuits
Clamping Level 50V
Jacks

RJ-45

Wires Protected 8-Wires

Telephone Circuit

Fuseless/Auto-resetting

Yes

Clamping Level 275V
Suppression Modes Metallic & Longitudinal
Jacks

RJ-11

Wires Protected 2-Wire, Pins 4 & 5

Cable and Satellite Circuits

HD 1080 i/p Ready Yes
Bi-directional

Yes

Shielded

Yes

Clamping Level 75V
Frequency Range 0MHz - 2.2 GHz
Insertion Loss < 0.5 dB
Connections Female “F”, Gold Plated