Eurosys 15pm – Peavey 15PM User Manual

Page 2

Advertising
background image

EuroSys 15PM

Powered Monitor Enclosure

OPERATING INSTRUCTIONS

WARNING! TO PREVENT SHOCK OR FIRE HAZARD DO NOT EXPOSE THIS APPLIANCE

TO RAIN OR MOISTURE. DO NOT REMOVE FROM CASE. NO USER SERVICEABLE

PARTS INSIDE. REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL.

REPLACE FUSE ONLY WITH ONE OF THE SAME TYPE AND SPECIFICATION.

Thank you for choosing Peavey's Eurosys 15PM powered monitor enclosure as part of your sound

reinforcement system. We take great pride in the design and manufacture of our units and you can expect

top performance and reliability. Your Eurosys 15PM has been rigorously tested before packing and

despatch to your dealer. It has been designed to run from a nominal 230 Volt AC mains supply.

1. AMPLIFIER INPUTS

Use to connect line level signals from the monitor send of the mixer. Two sockets are provided to

allow connection to further Eurosys 15PM powered monitors. (Daisy chaining).

2. VOLUME

This slider controls the level or volume of the enclosure.

3. 4 BAND GRAPHIC EQUALISER

Four sliders allowing up to +/- 12dB of adjustment at the centre frequencies of: - 100Hz , 1KHz ,

5KHz and 10KHz. Use to assist with any feedback problems.

4.

~ PILOT LIGHT

Illuminates when AC mains power is being supplied to the amplifier.

5. EXTENSION SPEAKER SOCKET

Allows connection of a further unpowered monitor with an impedance of 8 ohms. The power amplifier

will develop full power into 4 ohms. (150 Watts).

6. POWER SWITCH

Use to turn the Eurosys 15PM ON or OFF

7. MAINS CONNECTOR & FUSE HOLDER

An IEC 320 combined mains connector and fuse holder is fitted. A separate 3-wire mains cord fitted

with a moulded plug is supplied.

8. 13 AMP PLUG REPLACEMENT

As the colours of the wires in the mains lead or cord of this apparatus may not correspond with the

coloured markings identifying the terminals in your plug, proceed as follows:

- the wire which is coloured green and yellow must be connected to the terminal in the plug which is

marked with the letter E or by the earth symbol, or coloured green or green yellow.

- the wire which is coloured blue must be connected to the terminal which is marked with the letter N

or coloured black.

- the wire which is coloured brown must be connected to the terminal which is marked with the letter

L or coloured red.

WARNING - THIS APPARATUS MUST BE EARTHED

SPECIFICATIONS

POWER OUTPUT (TYPICALLY) POWER REQUIREMENTS

105 Watts into 8 ohms 325 Watts at 150 Watts output

150 Watts into 4 ohms

INPUT SENSITIVITY

MAINS VOLTAGE REQUIREMENTS

0.7 volt for 105 Watts into 8 ohms 230 Volts AC (only) 50/60 Hz

FUSE RATING

1.6 ampere anti surge.

IN CASE OF DIFFICULTY CONSULT YOUR AUTHORISED PEAVEY DEALER

Due to our efforts for constant improvement, features and specifications are subject to change

without notice.

Advertising