How to solve the conflict – pd side, Proposed solution – PowerDsine IEEE802.3 User Manual

Page 19

Advertising
background image

PowerDsine Presentation October 2005 Page 19

www.PowerDsine.com

How to solve the conflict – PD side

„ Proposed Solution

„ Effects on PD specifications

– PD operating voltage range: No effect. Remains 37-57V.

– PD classification in 802.3at (including Class 4) should be

mandatory and not optional

– The enhanced classification table will be divided to two parts:

(See details in “An Extended Classification Proposal- Proposal #1, Vancouver BC, Nov. 2005)

„

Part a: power classes that can work with either 44V or 51V.

„

Part b: power classes that can work only with 51V minimum at the
PSE.

– This may be documented in the Informative section of the

standard.