10.10.22.50(if-ip)[eth0]#reload
Running configuration has been changed.
Do you want to copy the 'running-config' to the 'startup-config'?
Press 'yes' to store, 'no' to drop changes : no
Press 'yes' to restart, 'no' to cancel : yes
The system is going down

6.0 Additional Information

For detailed information about configuring and operating guidance, set up procedures, and troubleshooting,
refer to the SN4520 & 4110 User Manual available online at

www.patton.com/manuals/SN4520-

4110.pdf

and the SmartWare Software Configuration Guide available online at www.patton.com/smart-

node.

A.0 Factory default IP address information

When you issue the reload command, the SmartNode will ask if you want to copy the
running configuration to the startup configuration. Since you just downloaded a con-
figuration file to the startup configuration you must answer this question with NO.
Otherwise, the downloaded configuration will be overwritten and lost!

Item

IP Addresss(es)

Network Mask

WAN interface Ethernet 0 (ETH 0/0)

DHCP client

DHCP client

*

LAN interface Ethernet 1 (ETH 0/1)

*

The SmartNode 4520 factory-default configuration includes a DHCP server run-
ning on the ETH 0/1. All Ethernet ports are pre-configured and active.

192.168.1.1

255.255.255.0

*DHCP server address range

192.168.1.10–192.168.1.19

255.255.255.0