Perlick Z2148 User Manual

Part no

Advertising
background image

Problem:

Beer flow is slower with Smart Coupler
than with standard Perlick coupler.

Probable Cause:

Beer Flow Control Handle is in CLEAN position.

Solution:

Slowly turn Beer Flow Control Handle to ON position.

Problem:

Beer does not flow after keg is tapped.

Probable Cause:

Smart Coupler has locked up.

Solution:

First, turn Beer Flow Control Handle to OFF position then
turn Beer Flow Control Handle to CLEAN position. Wait
five seconds then turn Beer Flow Control Handle to
ON position.

Probable Cause:

Beer Flow Control Handle is OFF.

Solution:

Turn Beer Flow Control Handle to CLEAN position.
Wait five seconds then turn Beer Flow Control Handle to
ON position.

Probable Cause:

Probe or Smart Coupler is dirty.

Solution:

Clean Smart Coupler.

Probable Cause:

Out of gas.

Solution:

Reestablish gas flow.

Problem:

Excessive foam.

Probable Cause:

Beer temperature too high. Excessive beer flow rate. Beer
is over-carbonated

Solution:

These problems are not caused by the Smart Coupler.
Follow established procedures to correct the problem.

* U.S. Patent #5,630,411

Form Z2148

04.06.04

8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060
Fax 414-353-7069Toll Free 800-558-5592 • E-Mail: [email protected] • www.Perlick.com

OPERATING INSTRUCTIONS

SMART COUPLER with Empty Keg Sensor

The Smart Coupler* combines a
standard Perlick single-valve keg
coupler with a specially-designed
keg sensor that eliminates the
line loss that normally follows
every empty keg. Fresh kegs can
be drawn off immediately. The
beer lines are always full of beer.

Saves time

Reduces beer waste

Increases beer profits

Reduces aggravation

Part No.

26000F

No. 26000F

Smart Coupler with Empty Keg Sensor

Perlick’s Empty Keg Sensor

No. 40125

(Probe Washer Not Included)

IMPORTANT!

To ensure your complete satisfaction,

please read these instructions before using Perlick’s Smart Coupler.

Troubleshooting

Retrofitting Single Valve Couplers

Perlick single valve keg couplers can be
retrofitted to function as Smart Couplers.
Simply replace the probe with Perlick’s
No. 40125 empty keg sensor.

1. Remove probe washer from

bottom of probe.

2. Remove retaining screw and

yoke assembly.

3. Lift probe out of body.

4. Install Perlick’s empty keg sensor.

When replacing probe washer
make sure the surface marked
up” faces the probe washer.

Advertising