Remote Loop Idle

(default)

The Remote Digital Loopback (RDL) test checks the performance

of both the local and remote Model 2715s, as well as the communica-
tion link between them. Data from the local DTE is sent across the
entire communication circuit and looped back to the local DTE.

The Model 2715 Initiating a RL can be in one of the following

states:

Idle

No user-controlled loopbacks are active.

TxPr

The Model 2715 is sending the preparatory phase pattern
lasting for approximately 2 -5 seconds.

WtAk

The Model 2715 is waiting for an acknowledgement from
the remote unit. If the remote unit does not respond, the
WtAk message will remain on the screen.

RxAk

The Model 2715 has received an acknowledgement from
the remote unit.

Tout

The Model 2715 is waiting before entering the Remote
Loopback test mode.

TM

The Model 2715 has successfully negotiated the Remote
Loopback test and is in control of the remote unit. You
may send a test pattern at this point by pressing:

c <spacebar>

TxTr

The Model 2715 is sending a Terminate Loopback mes-
sage to the remote unit. If the remote unit does not
respond, the local unit will return to the Idle state.

Tx1s

If the remote Model 2715 responds to the local Model
2715’s terminate loopback request, the local unit then
sends an all ones pattern before returning to the Idle
state

TxP

The Model 2715 is sending a test pattern while in Test
Mode

IdlP

The Model 2715 is sending a test pattern in place of data.
The Model 2715 is not in test mode.

The Model 2715 receiving a RL can be in one of the following states:

RxPr

The Model 2715 is receiving a preparatory pattern.

Sack

The Model 2715, upon receiving a preparatory pattern,
sends an acknowledgement message.

RL

The Model 2715 is in remote loopback mode.

RxTr

The Model 2715 is receiving a terminate loopback mes-
sage.

WE1s

The Model 2715 is waiting for a sequence of all ones and
will time out if it does not receive it.

IdleP

The Model 2715 is sending a QRSS, 511 or 2047 pat-
tern.

Off

The Model 2715 is in local loopback.

Test Pattern Idle

(default)

Options: Idle or Sending

To send a pattern, press the ‘c’ key and press <spacebar> to send the
test pattern. The “OK” message indicates the received test pattern is
error-free. The “BE” message indicates errors in the received pattern.
You may also hear a beep (from your termainal) once a second as long
as the unit detects a bit error in the pattern.

Idle

Indicates that Model 2715 is not sending a pattern.

Sending

Indicates that Model 2715 is sending a pattern.

Error Insertion Off

(default)

Options: On, Off

You may inject intentional errors into the test pattern by turning Error
Insertion ON. The Error (ERR) LED will blink once per second.

Selected Pattern

Options: QRSS, 511, or 2047

b

d

c

e