Eq series, High performance commercial pump – Pentair EQ SERIES User Manual

Page 2

Advertising
background image

Pump Body

Volute type, back pull-out design.

Port Size

6" – ANSI 150 bolted flange suction port.

1

4"– ANSI 150 bolted flange discharge port.

1

Material - Volute & Motor Adapter

Noryl

®

.

Impeller

Noryl

®

enclosed design.

Base

6061 Aluminum design, slotted for mounting ease.

Corrosion Prevention

All-plastic pump for maximum hydraulic performance

and corrosion prevention.

Hair and Lint Strainer

Material

Separate bolt-on Noryl

®

body with plastic

basket, Lexan

®

lid, and stainless steel bolts.

Size

6" ANSI 150 bolted flange suction and
discharge ports.

Pump Maximum Limits

Liquid Temperature: 104º F

Ambient Air Temperature: 104º F

Motor

Standard JM type.

Frame Size

NEMA “C” flange. 230/460V are open

drip-proof design.

Shaft

303 Stainless steel construction.

Design

3 to 15 HP, 3500 RPM, JM open drip-proof, continuous

duty, three-phase and single-phase (5 and 71/2 HP only).

Bearings

Double shielded, single row, deep groove type,

permanently lubricated.

Thermal Overload Protection

All models require external thermal overload protector.

Electrical

Power Supply Required

Three-phase pumps are 208 – 230/460. 3, 5 and 71/2 HP

single-phase models are available in 230V, 60 Hz. only.

For detailed efficiency curves for each model, please contact the factory.

1

Use ANSI class 150 plastic flange and

1

8

" thick class 150 full flange

gasket to make connection.

EQ Series

®

High Performance Commercial Pump

MatEriaLS and dESign

Performance curves

EQ Series

®

Performance curve

EQ Series

®

Waterfall

Pump

Advertising