Specifications – Pelco EH8100 User Manual

Page 9

Advertising
background image

C1407M-H (1/07)

9

Specifications

Electrical

Input Voltage

120 VAC (230 VAC optional) for heaters

Power Requirements

40 watts (EH8104)
80 watts (EH8106)

Connector

16-pin receptacle with jam nut

Mating Connector

MS-type connector (supplied)

Maximum Cable Distances
120 VAC

EH8104

EH8106

16 AWG (1.5 mm

2

)

4,477 ft (1365 m)

2,238 ft (682 m)

18 AWG (1.0 mm

2

)

2,821 ft (860 m)

1,410 ft (430 m)

20 AWG (0.5 mm

2

)

1,773 ft (540 m)

(1,252) 1,040 (316)

230 VAC

16 AWG (1.5 mm

2

)

16,449 ft (5,014 m)

8,224 ft (2,507 m)

18 AWG (1.0 mm

2

)

10,364 ft (3,159 m)

5,182 ft (1,579 m)

20 AWG (0.5 mm

2

)

6,514 ft (1,985 m)

3,257 ft (993 m)

Heater
EH8104

Two, 20 watts each, 120 VAC

EH8106

Two, 40 watts each, 120 VAC
Heaters are thermostatically controlled to come on at 40°F (4°C) and go off at 60°F (16°C)

General

Construction

Aluminum 6061 T6

Finish

Outside

Gray polyester powder coat

Inside Black

anodized

Dimensions

See Figure 3

Front Window

EH8104

4-inch diameter tempered glass, 0.225-inch thick

EH8106

6-inch diameter tempered glass, 0.225-inch thick

Camera Mounting

Multiple mounting holes on camera sled allow for linear adjustment

Maximum Camera/Lens Size

EH8104

3-inch diameter x 14-inch length (8 x 35 cm) or
14 (L) x 2.5 (W) x 2.5 (H) inches (35 x 6 x 6 cm)

EH8106

5-inch diameter x 18-inch length (13 x 46 cm) or
18 (L) x 4.0 (W) x 4.0 (H) inches (46 x 10 x 10 cm)

Enclosure

Mounting

Adjustable cradle secured with type 316 stainless steel bands

Purge Fitting

Standard Schraeder valve to allow enclosure to be filled with dry nitrogen

Purge Fitting

Prevents over-pressurization of enclosure

Weight

EH8104

8 lb (4 kg)

EH8106

15 lb (7 kg)

Advertising