Switch S1-8: Carrier Control Method

The setting for switch S1-8 determines whether the carrier is “constantly
on” or “controlled by RTS”. This setting allows for operation in switched
carrier, multipoint and/or hardware handshaking applications.

3.3 CONFIGURATION SWITCH SET “S2”

The DIP switches on S2 set word length, extended signaling rate,
RTS/CTS delay, V.52 and V.54 diagnostic test and 2- and 4-wire opera-
tion.

Table 3:

S2 Summary

S1-8

Setting

Off

Constantly on

On

Controlled by RTS

Position

Function

Factory Default

S2-1

Word Length

Off

S2-2

Word Length

Off

S2-3

Extended Signaling Rate

Off -2.5% to 1%

S2-4

RTS/CTS Delay

On

S2-5

RTS/CTS Delay

On

S2-6

V.52/V.54 Tests

Off Normal Operation

S2-7

2-Wire/4-Wire

Off

(4-Wire)

S2-8

Not Used

N/A

}

}

7 ms

10 bits