Preparing the Cabinet for Use –

Single Door Back Bar Cooler

Parts List

(2) Shelves.

Mini-Flourescent Light.

Shelf Clips.

Tools Required

#2 Phillips Screwdriver.

10” Crescent Wrench.

9

/

16

” Allen Wrench.

3

/

8

” Nut driver.

power Drill or Driver (for Leg Installation).

Plumbing

Features a floor drain with a

3

4

” female pipe thread

connection for disposal of condensate. Remove
bottom or side drain plug with Allen wrench and
attach

3

4

” male pipe to external drain.

Electrical

The cabinet must be connected to a separately
fused power source (see electrical specification
plate) and grounded in accordance with National
and Local Electrical Codes. Caution: Do not
attempt to operate the equipment on any other
power source than that listed on the Electrical
Specification plate.

Uncrating and Inspection

Remove all crating material before operating.
Carefully inspect cabinet for hidden damage. If
damage is discovered, file your claim immediately
with the transportation company. Perlick is
not responsible for damage in transit.

Installing Casters

(Optional)

Attach four casters to the cabinet bottom; rigid cast-
ers at the rear and swivel casters on the front. Use
the supplied

1

/

4

”- 20 x

3

/

4

” hex head self-tapping

machine screws.

Placing the Cabinet

Push the cabinet into place using rollers when
necessary. Important: Proper air flow around the
condensing unit is necessary for efficient operation.
Never obstruct the air flow in and out of the
condensing unit. A minimum of 2” clearance is
required from back.

Leveling the Cabinet

When the cabinet is in place, check installation with
carpenter’s level. When perfectly level, accumulated
water will drain out. A slight pitch to the drain side
will not harm the cabinet. Water may accumulate if
cabinet is pitched to the opposite side.

Installing Base Plate

(Optional)

Attach brackets to cabinet bottom in holes provided.
Use #10 self-drilling hex sheetmetal screws. (See
separate instructions, provided with kit). When
returning cabinet to upright position, be careful not
to bend brackets.

WARNING!

To avoid compressor damage,after returning
cabinet to an upright position, let unit stand for
24 hours before plugging it in and running the unit.