English osd (on screen display) controls – Pioneer PDP 424MV User Manual

Page 31

Advertising
background image

English

OSD (On Screen Display) Controls

24

En

Enabling/disabling remote control wireless
transmission
This function enables/disables remote control wireless
transmission.

Example: Setting “OFF”

Set “ADVANCED OSD” to “ON” in the main menu (1/
2), then perform the following operations.

On “IR REMOTE” of “OPTION3” menu, select “OFF”, then
press the MENU/SET button.

OPTION3

3 / 3

PREVIOUS PAGE

TIMER

PWR. ON MODE

KEY LOCK

IR REMOTE

LOOP OUT

ID NUMBER

VIDEO WALL

: LAST

: OFF

:

OFF

: OFF

: ALL

SEL.

ADJ.

EXIT RETURN

Information
IR REMOTE settings
ON: Enables remote control wireless transmission.
OFF: Disables remote control wireless transmission.
Set “OFF” to avoid unwanted control from other remote
controls.

Loop Out setting
When this feature is set to ON, the received signal will be
looped out.

Example: Setting “ON”

Set “ADVANCED OSD” to “ON” in the main menu (1/
2), then perform the following operations.

On “LOOP OUT” of “OPTION3” menu, select “ON”.

OPTION3

3 / 3

PREVIOUS PAGE

TIMER

PWR. ON MODE

KEY LOCK

IR REMOTE

LOOP OUT

ID NUMBER

VIDEO WALL

: LAST

: OFF

: ON

:

ON

: ALL

SEL.

ADJ.

EXIT RETURN

Information
LOOP OUT settings
ON: The received signal will be looped out via PC1
terminal or VIDEO1 terminal.
OFF: The received signal will not loop out.

* Even if LOOP OUT is ON, signals won’t be sent out if

POWER is being turned off.

To connect another display...
See page 3.
If the PC1 signal is present at the time the

power switched on...

The PC1 input will be displayed regardless of the setting
of LOOP OUT.

ID number setting
When using more than one of these displays, this function
sets ID numbers so that operation of the remote control
does not cause multiple monitors to operate at the same
time.

Example: Setting “2”

Set “ADVANCED OSD” to “ON” in the main menu (1/
2), then perform the following operations.

On “ID NUMBER” of “OPTION3” menu, select “2”.

OPTION3

3 / 3

PREVIOUS PAGE

TIMER

PWR. ON MODE

KEY LOCK

IR REMOTE

LOOP OUT

ID NUMBER

VIDEO WALL

: LAST

: OFF

: ON

: OFF

:

2

SEL.

ADJ.

EXIT RETURN

* To reset back to ALL

Press the CLEAR button.

Information
ID NUMBER settings
ALL: ID NUMBER will not be set.
1 to 256: ID NUMBER will be set.
When the ID NUMBER have been set
You can also set ID NUMBER for each remote control
to operate the plasma display individually. To do so,
see below.

To set the ID number for the remote control

Example: Setting “2”

Press the ID NO. SET button on the remote control.
The “ID NO. SET” screen appears.
On “ID NUMBER” of “ID NO. SET” menu, select “2”.

ID NO.SET

POSITION : 1

:

2

ID NUMBER

ADJ.

EXIT RETURN

* To reset back to ALL

Press the CLEAR button.

Video Wall setting
Use this feature to configure a 4-25 video wall.
Set “ADVANCED OSD” to “ON” in the main menu (1/
2), then perform the following operations.

On “OPTION3” menu, select “VIDEO WALL”, then press
the MENU/SET button.
The “VIDEO WALL” screen appears.

VIDEO WALL

DIVIDER

POSITION

DISP. MODE

AUTO ID

SCREEN

P. ON DELAY

ABL LINK

REPEAT TIMER

:

1

: NORMAL

: OFF

: OFF

: OFF

: OFF

SEL.

ADJ.

EXIT RETURN

Note: A contingency method of shutting off the electric
power should be used in cases of emergency during video
wall setup.

Advertising