Appendix a model 1082 specifications, A.1 transmission format, A.2 transmission line – Patton electronic 1082 User Manual

Page 25: A.3 clocking, A.4 distance, A.5 data rates, A.6 diagnostics, A.7 led status indicators

Advertising
background image

25

APPENDIX A

MODEL 1082 SPECIFICATIONS

A.1 TRANSMISSION FORMAT

Synchronous or asynchronous

A.2 TRANSMISSION LINE

Single unconditioned twisted pair

A.3 CLOCKING

Internal, external or receive loopback

A.4 DISTANCE

Distance, max, all data rates:

• 10.1 miles (16.4km) on 19 AWG (0.9mm) wire

• 7.2 miles (11.5 km) on 22 AWG (0.64mm) wire

• 5.0 (8 km) on 24 AWG (0.5mm) wire

• 3.4 (5.5 km) on 26 AWG (0.4mm) wire

A.5 DATA RATES

• Synchronous 19.2, 32, 56, 64,128, and 144* kbps

• Asynchronous 0–38.4 kbps

A.6 DIAGNOSTICS

V.52 compliant bit error rate pattern (511/511E pattern) generator and
detector with error injection mode; Local Line Loopback and Remote
Digital Loopback, activated by front panel switch or via serial interface

A.7 LED STATUS INDICATORS

TD, RD, DSL Link, NS (no signal), ER (error) and TM (test mode)

*

144 kbps data rate is only available on the Model 1082/144.
19.2 kbps rate is available on all Model 1082 series modems

except

for the 1082/144.