Connection examples, Aes/ebu connections, Ad8hr daisy chain connection – Pacific Digital AD8HR User Manual

Page 10: Aes/ebu connections ad8hr daisy chain connection

Advertising
background image

10

Connection Examples

AES/EBU Connections

Use a D-sub 25-pin AES/EBU cable to connect a
digital audio device that supports the AES/EBU
format. To connect a Yamaha PM5D or DM2000 to
the AD8HR, first you must install an optional I/O card
(MY8-AE, MY8-AE96S, MY8-AE96, or MY16-AE) in
the PM5D or DM2000.

AD8HR Daisy Chain Connection

You can connect multiple AD8HRs to a Yamaha
PM5D or DM2000. Connect [HA REMOTE]
connector 1 of the first AD8HR to the COM connector
of the DM2000, and connect [HA REMOTE]
connector 2 to [HA REMOTE] connector 1 of the
second AD8HR. Set the [PC RS422] switches on both
AD8HRs to RS422. Specify the DM2000 as the
wordclock master, and set the wordclock source on the
AD8HR to DIGITAL OUT A.

Connection Examples

DIGITAL OUT A/B

AD8HR

+48V

HPF

dB

96kHz

88.2kHz

48kHz

44.1kHz

+48V

OFF ON

MASTER

WORD CLOCK

Digital audio devices

(PM5D, DM2000, etc.)

Analog in x 8

Optional I/O card

AES/EBU cable

COM

SLOT 1

SLOT 2

HA REMOTE 2

HA REMOTE 2

DIGITAL
OUT A

HA REMOTE 1

HA REMOTE 1

AD8HR #1

+48V

HPF

dB

96kHz

88.2kHz

48kHz

44.1kHz

+48V

OFF ON

MASTER

WORD CLOCK

DIGITAL
OUT A

AD8HR #2

+48V

HPF

dB

96kHz

88.2kHz

48kHz

44.1kHz

+48V

OFF ON

MASTER

WORD CLOCK

Digital audio devices

(PM5D, DM2000, etc.)

Analog in x 8

Analog in x 8

Advertising