Reliability, Safety and emi, Environmental – Planar EL640.480-AF1 User Manual

Page 13

Advertising
background image

EL640.480-AF1 VGA Operations Manual (020-0349-00A)

11

Reliability

The MTBF (mean time between failure) is a minimum of 50,000 hours at 25°C
ambient, except for performance characteristics with an otherwise specified
life expectancy.

Safety and EMI

The display will not inhibit the end product from obtaining these certifications:

Safety UL544,

IEC950

EMI

FCC Part 15/J, Class B
EN55022 Level B

Environmental

Table 7. Environmental Characteristics.

Temperature

Operating
Non-Operating
Operating Survival

-5 to +55°C
-40 to +75°C
-20 to +65°C

Humidity

Non-condensing

93% RH max, @ 40°C

per IEC 68-2-3.

Altitude

Operating
Non-Operating

0 to 5 km (16k ft)
0 to 18 km (58k ft)

per IEC 68-2-13.

Vibration

Random

0.05 g²/Hz

ASD level, 20-500 Hz per
IEC 68-2-36, test Fdb

Shock

Half sine wave

100 g, 4 ms

18 (3 each, 6 surfaces) per
IEC 68-2-27, test Ea

Advertising