Connections

Precautions when controlling the

AK-HC1500 from the AW-CB400

The AK-HC1500 supports the AK-HRP150 protocol and
AW-CB400 protocol, and it is the AK-HRP150 protocol
which was set before the AK-HC1500 was shipped from the
factory.
When controlling the AK-HC1500 using the AW-CB400,
follow the steps below to change the protocol setting of
AK-HC1500 from AK-HRP150 to AW-CB400.

When changing the protocol before installation

Refer to the operating instructions of the AK-HC1500,
and change the protocol.

When changing the protocol after installation

Proceed with the installation following the steps given

in the section entitled “Installation”.

Loosen the two top cover open/close bolts of the

camera housing, and open the top cover.

Set the power switch of the AC adapter to ON.

When the power of the AK-HC1500 has been

turned on, refer to the operating instructions of the
AK-HC1500, and change the protocol. (Change the
PROTOCOL setting on the SETTING menu to “4.”)

Set the power switch of the AC adapter to OFF.

Connections with AC adapter

 Disconnect the AC power cable which was already

attached.

 The cable used is purchased locally. Purchase a water-

proof cable designed to be used outdoors.

 Use a cable which has a high enough capacity (AC 120 V

2 A or more).

 Pass the cable through the rubber bushing for the AC

power input cable, and tighten it securely so that rain
water or drops of water will not seep inside.
[Thickness of compatible cable: 1/4” to 5/16” (6.5 to 8.5 mm)
diameter]

 Attach the power line (N, L) to the terminal block.

 Attach the ground line (FG) to the grounding screw (

).

AC IN

DC15 V

OUT

AC power

input cable

Rubber bushing

FG

N

L

Advertising