10

5. Click on Select.

The File Selection Window appears (see

Figure 4

).

6. Select an existing UNIX directory and configuration image file to be sent to the AAC, and click OK.

NOTE

You must not select a configuration image file that was
uploaded from another AAC. Each configuration image
contains information and options specific to the particular
AAC from which the configuration image was transferred.

The File Selection Window disappears.

7. Click on Download.

8. Click Apply to begin the operation.

The percentage gauge in the center of the Upload/Download window displays the progress of the
operation (see

Figure 3

). The operation is complete when the percentage gauge reaches 100% and

Operation Complete is displayed at the bottom of the window.

The time required to download a configuration image from the HP OpenView host to an AAC could
exceed twenty minutes depending on the size of your network and its configuration and transmission
speed.

9. Click Close.

10. Select the Terminal Interface window. A message is displayed:

Transfer is successful. Press any key to continue.

11. PRESS:

Enter

The following message is displayed:

A reboot is required to activate the new configuration.
OK to reboot the system (y/n)?

12. TYPE:

y

The AAC is reset and all options contained in the downloaded configuration image are applied.