A.7 fiber optic link budget, Transmit power, Receiver sensitivity – Patton electronic 2300M User Manual

Page 15: Delay time, Typical fiber max. distance, A.8 standards, A.9 led status indicators, Fiber optic link budget, Standards, Led status indicators

Advertising
background image

15

A.7 FIBER OPTIC LINK BUDGET

Transmit power

• 2300M: -16.8 dBm (typical)

• 2310M: -12 dBm (typical)

• 2311M: -12 dBm (typical)

• 2312M: -16.8 dBm (typical)

Receiver Sensitivity

• 2300M: -33.5 dBm (typical)

• 2310M: -28 dBm (typical)

• 2311M: -28 dBm (typical)

• 2312M: -33.5 dBm (typical)

Delay Time

• 2300M: 5µs per km (typical)

• 2310M: 5µs per km (typical)

• 2311M: 5µs per km (typical)

• 2312M: 5µs per km (typical)

Typical Fiber Max. Distance

• 2300M—1.24 mile (2 km)

• 2310M—1.24 mile (2 km)

• 2311M—1.24 mile (2 km) in 10Base-FL mode/300 m in 100Base-SX mode

• 2312M—1.24 mile (2 km)

A.8 STANDARDS

IEEE802.3 and IEEE 802.3u (10Base-T, 10Base-FL, 100Base-TX,
100Base-SX, and 100Base-FX)

A.9 LED STATUS INDICATORS

Power, Twisted-Pair/Copper Link and Activity, Fiber Optic Link and Activity

Advertising
This manual is related to the following products: