Troubleshooting guide – Porter-Cable CH250 User Manual

Page 18

Advertising
background image

18 — ENG

PROBLEM

CAUSE

CORRECTION

Engine will not start

No electrical output

Repeated circuit breaker tripping

Generator overheating

1.

Low on fuel.

2.

Ignition switch in "Off" position.

3.

Faulty spark plug.

4.

Choke in wrong position.

5.

Unit loaded during start-up.

6.

Spark plug wire loose.

1.

Faulty receptacle.

2.

Circuit breaker kicked out.

3.

Defective capacitor.

4.

Faulty power cord.

1.

Overload

2.

Faulty cords or equipment.

1.

Generator overloaded.

2.

Insufficient ventilation.

1. Add fuel.

2. Turn to "ON" position

3. Replace spark plug.

4. Adjust choke accordingly.

5. Remove load from unit.

6. Attach wire to spark plug.

1. Have Service Center replace.

2. Depress and reset.

3. Have Service Center replace

capacitor.

4. Repair or replace cord.

1. Reduce load.
2. Check for damaged, bare, or

frayed wires on equipment.
Replace.

1. Reduce load.

2. Move to adequate supply of

fresh air.

TROUBLESHOOTING GUIDE