2

Scroll Air Compressors

GREASE DELIVERY

SLAE03

SLAE05

Bearing

1st Time

2nd Time

1st Time

2nd Time

Orbit Scroll Bearing

5 Times

3 Times

6 Times

4 Times

Pin Crank Bearing Orbit Scroll Side

5 Times

3 Times

6 Times

4 Times

Pin Crank Bearing Housing Side

5 Times

3 Times

6 Times

4 Times

NOTE: Each pump of the grease gun equals 0.65 grams of grease.

Figure 2

Figure 3

45°

Grease
Fitting

Grease Gun

Extension
Adaptor

Counter
Weight

Key
Way

Extension
Adaptor

Orbit Scroll
Bearings

Grease Fitting

Housing
Side Bearings

Grease
Gun

Plastic
Dust Cap

3 Grease Caps

Air End Pulley & Cooling
Fan (Not Shown)

Fan Duct Shroud
(Not Shown)

Per OSHA
regulations, ALL

power must be locked out before per-
forming any maintenance.

This service should
be performed by an

authorized Powerex Service Center to
avoid failure.

1. Remove the plastic dust cap. Use

only one of two locations found on
the air end (See Figure 2).

2. Rotate the compressor pulley until

the grease fitting is visible through
the dust cap hole (See Figure 2).
This will allow regreasing of the
main bearings.

3. Use a grease gun extension adaptor

to engage the grease fitting and
supply the proper volume of grease
as indicated on the grease delivery
chart (See Grease Delivery chart
below & Figure 2).

Use only Powerex
genuine grease.

Pump grease gun before feeding (this
eliminates air from the grease passage
of the extension adapter. (Complete
Grease Kit Part Number IP616200AJ and
Grease Tube Part Number IP600000AV).

4. Replace plastic dust cap.

The bearings on the scroll compressor
are regreaseable to allow extended
compressor life. Service should be per-
formed every 10,000 hours of opera-
tion.

1. Remove the V-Belts and the fan

cover.

2. Remove the air end pulley and cool-

ing fan with a gear puller (See
Figure 3).

!

CAUTION

!

CAUTION

!

WARNING

Grease Compressor
Bearings

10,000 HOURS - MAINTENANCE

3. Remove the fan duct shroud.

4. Remove the three grease caps. Do

not attempt to loosen or tight-
en the bolt.

5. Grease all three pin crank bearings

(See Figures 3, 4 & 5 and Grease
Delivery Chart below).

The grease fitting,
located in the cen-

ter of the pin crank bearing, feeds only
the orbit scroll side bearing. Use a
needle adapter to supply grease to the
housing side bearing. PUMP GREASE

!

CAUTION

GUN BEFORE FEEDING TO ELIMINATE
AIR FROM GREASE PASSAGE OF THE
NEEDLE ADAPTER. Hold grease gun for
5 - 10 seconds after feeding to prevent
grease blowback from the grease fit-
ting.

6. Replace grease caps, fan shroud,

pulley, etc.

(See Scroll Service and
Maintenance Video for Audio and
Visual Instructions.)

GREASING PIN CRANK BEARINGS