5.2.2 REMOTE ANALOG LOOP

The second test mode is Remote Analog Loop. To enter this

mode, set one of the Model 1050s (local) in test mode by depressing
the "Loopback Test" switch. Any characters sent from the remote 1050
will be returned to it (see Figure 5). If no characters are echoed back,
check the wiring between the two Model 1050s. Be sure to wire the
units according to the instructions in Section 4.0 Installation.

11

12

APPENDIX A

PATTON MODEL 1050 SPECIFICATIONS

Transmission Format: Asynchronous

Transmission Line:

19 to 26 AWG twisted pair

Range:

7 miles on 24 AWG twisted pair @ 1200 bps

Serial Interface:

EIA RS-232 (CCITT V.24), DB-25 female

Twisted Pair Interface: Terminal blocks, RJ-11 jack

Data Rates:

0 - 38,400 bps

Applications:

Point-to-point, Multipoint

Indicators:

Tri-state for transmit data, receive data, and
test

Diagnostics:

Local Analog Loopback (LAL), Remote
Analog Loopback (RAL)

Optical Isolation:

2500V RMS (minimum)

Power Supply:

Wall mount, 9-12VAC, 200ma

Temperature Range:

0-60°C (32-140°F)

Altitude:

0-15,000 feet

Humidity:

5 to 95% noncondensing

Dimensions:

1.58”H x 4.16”W x 3.75”D

Weight:

13.2 oz. (without transformer)

RD

TD

TD

RD

Local 1060

In Normal Mode

Remote 1060

In Normal Mode

TX+

TX-

RX-

RX+

RX+

RX-

TX-

TX+

RD

TD

TD

RD

Local 1060

In Loopback Mode

Remote 1060

In Normal Mode

RX+

RX-

TX-

TX+

TX+

TX-

RX-

RX+

Figure 5. Loopback Test Modes

Advertising