MAX® 4300-PM BACK PANEL FEATURES

1. Circuit Breaker:
Automatically opens
when the current load
is greater than 15
Amps. Push to reset.

5. Universal TV Coaxial
Jacks
2 pairs of bidirectional
protection circuits optimized for
satellite, cable, and antenna
TV signal lines.

3. Outlet Bank 1
Four switched outlets with linear filtration technol-
ogy (LiFT) controlled by the front panel Power
Button.
LiFT EMI/RFI noise filtration is provided by a two-
stage tapped Pi filter circuit which also provides
noise isolation from all four outlets in Bank 2.

2. Outlet Bank 2
Four switched, high-current outlets controlled by
the front panel Power Button.
The High Current outlet provides power from a low
impedance noise filtration circuit that does not limit
the current to your equipment. Its output is noise
isolated from Outlet Bank 1.

6. Main Power
Must be plugged into a
properly wired & grounded
3-wire outlet

.

4. LAN Jacks
Protection circuits for 10/100 baseT
Ethernet lines. Incoming LAN line MUST
be plugged into the LINE jack. Patch cord
to the equipment MUST be plugged into
the EQUIP jacks. 8 wire protection, 50V
clamping.

7. Ground Lug:
Provides a common grounding
point for equipment with separate
ground leads

8. Phone Jacks
Protection circuits for standard telephone
or pay-per-view lines. Phone circuit is
autoresetting. Incoming phone cord MUST
be plugged into the LINE jack. Patch cords
to the equipment (satellite receiver, digital
video recorder, telephone, etc.) MUST be
plugged into the EQUIP jacks.

MAX® 4300-PM SPECIFICATIONS

UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING

General________________________________________________________________
Dimensions...................................17 in. W x 7.75 in. D x 1.75 in H, (2.125 in. Including feet)
Weight.........................................................................................................................6.5 lbs.

AC Power_______________________________________________________________
Line Voltage.........................................................................................................120V, 60Hz
Total Current Capacity.....................................................................................................15 A
UL1449 Suppression Rating...........................................................................................330V
Protection Modes.............................................................................................L-N, L-G, N-G
Initial Clamping Level....................................................................................................200V
Energy Dissipation..............................................................................................1650 Joules
Peak Impulse Current........................................................................................65,000 Amps
Catastrophic Surge Circuit................................................................................................Yes
Thermal Fusing:...............................................................................................................Yes

Over-voltage shutoff....................................................................................142 VAC ± 5 VAC
Under-voltage shutoff....................................................................................90 VAC ± 2 VAC

EMI/RFI Noise Filtration___________________________________________________
Bank 1, Linear Filtration Switched Outlets.......................................60 db, 100 KHz – 2 MHz
Bank 2, High Current Switched Outlets...........................................49 db, 100 KHz – 2 MHz

LAN Circuits_____________________________________________________________
Clamping Level.............................................................................................................50V
Jacks..........................................................................................................................RJ-45
Wires Protected:.....................................................................................................8-Wires

USB Circuit_____________________________________________________________
Jacks...............................................................................................................................USB
Power Delivery......................................................................................................5 x 100 mA

Telephone Circuit________________________________________________________
Fuseless/Auto-resetting..................................................................................................Yes
Clamping Level.............................................................................................................260V
Capacitance....................................................................................................30pf (approx.)
Suppression Modes..........................................................................Metallic & Longitudinal
Connections................................................................................................................RJ-11
Lines Protected.......................................................................................2-Wire, Pins 4 & 5

Cable and Satellite TV Circuits______________________________________________
HD Ready.........................................................................................................................Yes
Bidirectional......................................................................................................................Yes
Shielded...........................................................................................................................Yes
Clamping Level................................................................................................................75V
Frequency Range.........................................................................................0MHz - 2.2 GHz
Insertion Loss............................................................................................................< 0.5 dB
Connections......................................................................................Female “F”, Gold Plated

MODEL M4300-PM

MASTER CARTON

UNIT CARTON

Dimensions Weight Dimensions Weight UPC Qty Dimensions Weight UPC

17” x 7.75” x 1.75” 6.5 lbs 19.5” x 12” x 4.625” 8 Lbs 0 50616 00818 1 2 20” x 12.75” x 10.75” 17.5 Lbs 5 00 50616 00818 6

2.125

” H with feet

1690 Corporate Circle, Petaluma, CA. 94954 800-472-5555 or 707-283-5900 Fax 707-283-5901 www.panamax.com

© 2007 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax

Specifications are subject to change due to product upgrades and improvements.

L586 REV A 5/07