0 care of the boiler, 3 fault indication, Table of error codes – Baxi Potterton Cold HE A User Manual

Page 8

Advertising
background image

5.0 Care of the Boiler

8

© Baxi Heating UK Ltd 2008

5.1

Cleaning the Outer case

The painted panels should be wiped with a damp cloth and
then dried completely. DO NOT USE ABRASIVE
CLEANING AGENTS.

5.2

Protection & Precaution

1. The boiler incorporates an integral frost protection feature

that will operate in both modes. If the boiler temperature falls

below 5° C, then the boiler will operate until the water

temperature has been raised.

2. If a system frost thermostat has been fitted (your installer

will be able to advise you), then to operate correctly and

protect your system, the gas and electricity must be left on and

the appliance set in the central heating mode.

3. The boiler incorporates an integral pump protection feature

which continually monitors the time since the pump last

operated. To prevent seizure, the pump will operate for

approximately 1 minute if it has not run in the last 24 hours.

5.3

Fault Indication

1. If a fault occurs on the boiler an error code may be shown

on the facia display (Fig. 5).

2. The codes are either two or three digit, preceded by the

letter 'E'. For example, code E133 will be displayed by 'E1'

alternating with '33'. E50 is shown as 'E' then '50'.

3. E20, E28, E50, E125 & E160 indicate faulty components.

You should make a note of the displayed error code and

contact your installer or service engineer.

4. If E110 or E130 is displayed overheat of the primary water

or flue system has occurred. Turn the selector switch to the

reset position and hold for at least 5 seconds. If the boiler

does not relight, or the code is displayed regularly contact your

installer or service engineer.

5. E119 is displayed when the primary water pressure is less

than 0.5 bar. After repressurising the system the boiler should

operate. Your installer will be able to advise you about the

method of repressurising. See page 6 for further details.

6. E133 indicates that the gas supply has been interrupted,

ignition has failed or the flame has not been detected. Ensure

that the gas supply has not been turned off, and turn the

selector switch to the reset position and hold for at least 5

seconds. If the boiler does not relight, or the code is displayed

regularly contact your installer or service engineer.

Central Heating NTC Fault

Flue NTC Fault

Hot Water NTC Fault

Safety Thermostat Operated

Water Pressure Switch Not Operated

Circulation Fault (Primary Circuit)

Flue NTC Operated

Interruption Of Gas Supply or Flame Failure

Fan or Fan Wiring Fault

E20

E28

E50

E110

E119

E125

E130

E133

E160

Table of Error Codes

Reset

bar

0

1

2

3

4

1

2

3

4

5

PM

7

8

9

10

11

12

1

2

3

4

5

A

M

7

8

9

10

11

12

0

Display

Then

Fig. 5

Advertising