Patton electronic 1004S User Manual

Page 7

Advertising
background image

RJ-45 Cable (4-Wire)

SIGNAL

PIN#

PIN#

SIGNAL

GND

2-----------------------7

GND

RCV-

3-----------------------5

XMT-

XMT+

4-----------------------6

RCV+

XMT-

5-----------------------3

RCV-

RCV+

6-----------------------4

XMT+

GND

7-----------------------2

GND

RJ-11 Cable (2-Wire)

SIGNAL

PIN#

PIN#

SIGNAL

XMT+

3-----------------------3

XMT+

XMT-

4-----------------------4

XMT-

RJ-45 Cable (2-Wire)

SIGNAL

PIN#

PIN#

SIGNAL

XMT+

4-----------------------4

XMT+

XMT-

5-----------------------5

XMT-

Connection to ground is optional

4.2 WIRING FOR MULTIPOINT CIRCUITS

The Model 1004 supports multi-point applications using either a

star or daisy chain topology. Both topologies require special wiring, as
well as specific DIP switch settings for master and slave units. Note:
Refer to Section 3.2.2 for multipoint DIP switch settings.

4.2.1 STAR TOPOLOGY

Using a star topology, you may connect several Model 1004s

together in a master/slave arrangement. Maximum distance between
the units will vary based upon the number of drops, data rate, wire
gauge, etc. Call Technical Support for specific distance estimates.

12

4.1.2 TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45

The RJ-11 and RJ-45 connectors on the Model 1004’s twisted pair

interface are pre-wired for a standard TELCO wiring environment. The
signal/pin relationships are shown below:

RJ-11

SIGNAL

RJ-45

SIGNAL

1 ...................GND

1 ...................N/C

2 ...................RCV-

2 ...................GND

3 ...................XMT+

3 ...................RCV-

4 ...................XMT-

4 ...................XMT+

5 ...................RCV+

5 ...................XMT-

6 ...................GND

6 ...................RCV+
7 ...................GND
8 ...................N/C

Connection to ground is optional

AT&T standard modular color codes

When connecting two Model 1004’s, it is necessary to use a

crossover cable. The diagrams below show how a crossover cable
should be constructed for the following environments: 4-wire RJ-11,
4-wire RJ-45, 2-wire RJ-11 or 2-wire RJ-45.

RJ-11 Cable (4-Wire)

SIGNAL

PIN#

PIN#

SIGNAL

GND

1-----------------------6

GND

RCV-

2-----------------------4

XMT-

XMT+

3-----------------------5

RCV+

XMT-

4-----------------------2

RCV-

RCV+

5-----------------------3

XMT+

GND

6-----------------------1

GND

Connection to ground is optional

11

1
2
3
4
5
6
7
8

1
2
3
4
5
6

Advertising