Monitoring the Unit

4-8

7986-A2-GB20-10

December 1998

Use the virtual function keys to page through the intervals and clear statistics.

This Field . . .

Contains . . .

Current Interval
Timer

The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds (15 minutes).
This counter resets every 15 minutes.

Error Events
Counter

A running total of CRC errors. Range 0 – 65535. This counter
resets when the near-end data is cleared.

Current Interval

Performance data for the current 15 minutes.

Interval

xx

Historical performance data for up to 96 15-minute intervals
(24 hours) where the value of

xx is from 01 to 96.

Worst Interval

The number of the interval with the worst (highest) performance
data for both the near- and far-end statistics. If two or more
intervals are equal, the oldest interval is displayed.

Near and Far TOT

A 24-hour running total of the near- and far-end performance
statistics.