SW1-6 and SW1-7 Clock Modes

Use Switches SW1-6 and SW1-7 to configure the 2707 for internal,
external, or receive recover clock mode.

SW1-8: Enable/Disable Loop Tests from DTE

Use Switch SW1-8 to allow Model 2707 to enter loopback tests when the
DTE raises the appropriate loop request pin.

Table 3:

SW1-6 and SW1-7 Clock Modes

SW1-6

SW1-7

Clock Mode

ON

ON

Network (Received Recovered)

ON

OFF

Internal

OFF

ON

External

OFF

OFF

Network (Received Recovered)

Network Clock

Transmitter timing is derived using
the received line signal (received
recovered) from the network.

Internal Clock

Transmitter timing is derived from
an internal clock source.

External Clock

Transmitter timing is derived from
DTE terminal timing.

SW1-8

Setting

Off

Response to DTE Loopback Request Enabled

On

Response to DTE Loopback Request Disabled