3.2 DETAILED SWITCH SETTINGS

This section provides detailed information about the function of

each DIP switch and lists all possible settings.

Switch 1: Hardware/Software Control

The setting for Switch 1 determines whether the Model 2025 will

have either hardware or software flow control.

Switch 2: LED Indicator

The setting for Switch 2 determines whether the LED indicator is

enabled or disabled.

5

Flow Control SW1
Hardware

OFF

Software

ON

LED

SW2

Enabled

ON

Disabled

OFF

DIP SWITCH SUMMARY TABLE

Position

Function

Factory Default

SW1

Flow Control

Off

SW2

LED Indicator

On

SW3

Data, Parity, Stop Bits

Off

SW4

Data, Parity, Stop Bits

Off

SW5

Data, Parity, Stop Bits

Off

SW6

Data Rate

Off

SW7

Data Rate

Off

SW8

Data Rate

Off

Hardware

Enabled

8B, NP, 1S

9600 bps

}

}

Switch 3 through 5: Data, Parity and Stop Bit

Switches 3 through 5 are used to specify the data, parity and stop

bits. The following table shows the settings that may be used:

Switches 6 through 8: Frequency and Data Rate

Switches 6 through 8 determine the frequency and data rate. The

following chart shows the settings that may be used.

6

7B

EP

1S

ON

ON

ON

7B

OP

1S

OFF

ON

ON

7B

NP

2S

ON

OFF

ON

7B

EP

2S

OFF

OFF

ON

7B

OP

2S

ON

ON

OFF

8B

EP

1S

OFF

ON

OFF

8B

OP

1S

ON

OFF

OFF

8B

NP

1S

OFF

OFF

OFF

Stop

Data

Parity

Bit

SW3

SW4

SW5

300

OFF

OFF

ON

600

ON

OFF

ON

1200

ON ON

OFF

2400

OFF

ON

ON

4800

ON

ON

ON

9600

OFF

OFF

OFF

19200

ON

OFF

OFF

38400

OFF

ON

OFF

Model 2025