S1-3 through S1-6: Not Used

S1-7 and S1-8: RTS/CTS Delay

The combined settings for switches S1-7 and S1-8 determine the

amount of delay between the time the Model 1018RC “sees” RTS and
when it sends CTS. Currently, the Model 1018RC does not have
optional delay settings. “No Delay” is defined as between 500 nsec and
1 msec. The switches should remain in the “OFF” position.

S1-7

S1-8

Setting

Off

Off

0 mS delay
No other valid settings

3.1.2 CONFIGURATION SWITCH SET “S2”

The eight DIP switches on pack S2 set Digital Reset, Carrier

Control, Link Clocking, Async Data Rate and Microprocessor Reset.
Factory default settings are summarized in Figure 4, below.
Descriptions of all possible S1 switch settings, including the Patton
factory default settings, are found on on pages 6 and 7.

6

3.1.1 CONFIGURATION SWITCH PACK “S1”

The eight DIP switches on pack S1 set Remote Test Activation and

RTS/CTS Delay. Descriptions of all possible S1 switch settings,
including the Patton factory default settings, are found on on pages 4
and 5.

S1-1: DTE Control of LAL

The setting for switch S1-7 determines whether the Local Analog

Loopback test on the Model 1018RC can be activated via pin 18 of the
RS-232 interface.

S1-1

Setting

On

Enabled

Off

Disabled

S1-2: DTE Control of RDL

The setting for switch S1-7 determines whether the Remote Digital

Loopback test on the Model 1018RC can be activated via pin 21 of the
RS-232 interface.

S1-2

Setting

On

Enabled

Off

Disabled

5

S2 SUMMARY TABLE

Position

Function

Factory Default

S2-1

V.54 Disable

Off

Normal

S2-2

Control of Carrier

On

Ctrl by DTR

S2-3

Link Clocking

On

S2-4

Link Clocking

On

S2-5

Async Data Rate

On

S2-6

Async Data Rate

On

S2-7

Async Data Rate

On

S2-8

Microprocessor Reset

Off

Normal

57.6 Kbps

}

Figure 4. Summary of DIP switch default settings for S2

Internal

}

S1 SUMMARY TABLE

Position

Function

Factory Default

S1-1

DTE Control of LAL

On Enabled

S1-2

DTE Control of RDL

On Enabled

S1-3

Not Used

Off

S1-4

Not Used

Off

S1-5

Not Used

Off

S1-6

Not Used

Off

S1-7

RTS/CTS Delay

Off

S1-8

RTS/CTS Delay

Off

N/A

0 mS

}

}

Figure 3. Summary of DIP switch default settings for set S1