Chapter 8 loop back reply – Planet Technology FT-1205A User Manual

Page 18

Advertising
background image

1

Chapter 8 Loop Back Reply

The FT-1105A / FT-1205A supports auto loop back reply while
receive loop back test packets on fiber port. Enable this function
to tell the converter to reply fiber signals request from Web
Smart media converter, such as PLANET FT-90x. You can use
this to check whether the converter can communicate with
partner converter. Please refer to the following figure.

Note

For FT-1105A only, while enable the Loop Back
Reply function, the Port-2 (TP) must be link up.

Advertising