Front panel – Panasonic AW-PS300 User Manual

Page 6

Advertising
background image

-4-

t

AC 120V Inlet [AC IN](AC 3P Inlet)

Connect the supplied AC cable.

y

Option Switch Terminal (OPTION SW CONTROL
OUT) (2P Terminal Board)

A relay switch capable of controlling the contact to
short or open from a Control Panel (AW-RP301, AW-
RP305, AW-RP501, or AW-RP505). The terminal board
has a maximum capacity of 120 V, 1 A (AC/DC), and is
valid when it is connected to OPTION SW CONTROL IN
Terminal

u on the pan/tilt head.

u

Option Switch Control Input Terminal (OPTION SW
CONTROL IN) (1P Terminal Board)

Connect it to OP Output Terminal on the pan/tilt head
when controlling OPTION SW CONTROL OUT Terminal

AC IN

LAMP AC OUT

100V 500W

OPTION SW

CONTROL OUT

OPTION SW
CONTROL IN

LAMP

CONTROL

OP

S

C

DC 15V

OUT

+

FRONT PANEL

y to short or open, using a cable (to be locally pur-
chased) with a nominal cross section of 0.3 mm

2

or

more that meets the UL specifications. The maximum
allowable cable length is 30 meters.
Applicable Wire

Solid wire:

ø1.02 (AWG 18)

Stranded wire:

0.75 mm

2

Usable wire range

Solid wire:

ø0.64 to ø1.02
(AWG 22 to 18)

Stranded wire:

0.3 mm

2

to 0.75 mm

2

(AWG 22 to 20)
Strand diameter: ø0.18 or more

Standard bare end length

10 mm