Panamax MAX 4400 User Manual

Instructions max

Advertising
background image

INSTRUCTIONS MAX

®

4400

Thank you for choosing Panamax.
The MAX

®

4400 is designed to

provide AC power distribution and
maximum protection for audio/
video equipment.

Inductorless Noise Filtration
Capacitive noise filtration allows
amplifiers and powered sub-
woofers to perform to their full
potential. When the movie thun-
ders with a terrific explosion or
when the music reaches a climac-
tic crescendo, an amplifier has to
rapidly draw large amounts of cur-
rent to replenish its power supply
capacitors. Traditional line condi-
tioners impede this current draw,
in effect, starving an amplifier and
resulting in a flat, dead sound.
The MAX

®

4400 provides clean,

filtered power to amplifiers but has
no current-limiting components to
impede performance.

INSTALLING THE MAX

®

4400

NOTE: The MAX

®

4400 and the

connected equipment must be
indoors and in the same building.

1. Plug the MAX

®

4400 directly

into a properly grounded 3-wire
AC outlet*.

2. Turn the MAX

®

4400 on.

3. Plug in one of the pieces of
equipment you want to protect and
turn the equipment on.

If the equipment is working cor-
rectly, continue to plug in and turn
on your equipment.

In the extremely unlikely event that
everything does not work perfectly,
stop and read the troubleshooting
section. If you continue to have
problems, call PANAMAX
Customer Relations Department at
800-472-5555, USA and Canada.

*Many old buildings are inade -
quately wired. It is very common
for a building to be improperly
grounded. Building wiring and
grounding must conform to appli-
cable NEC (USA) or CEC (Canada)
codes for the PANAMAX connect-
ed equipment policy to be valid.

TROUBLESHOOTING

There is no AC power to my
equipment, or my equipment
doesn’t turn on

.

Make sure that the MAX

®

4400 is

plugged into a working AC outlet.
Check all AC connections.

Make sure the MAX

®

4400 and

connected equipment is turned on.
If you are using the 12VDC trigger,
make sure that the source is actu-
ally supplying the voltage needed
to activate the MAX

®

4400.

Check to see if the circuit breaker
on the MAX

®

4400 needs to be

reset (press in).

The MAX

®

4400 circuit breaker

disconnects AC power from the
connected equipment.
You have exceeded the ampere rat-
ing for your surge protector.

As a temporary fix, disconnect one
or more pieces of equipment. Ask
your dealer about additional PANA-
MAX products that may be
required.

If you continue to have trouble
with your MAX

®

4400 or this sec-

tion has not fixed the problem,
please call PANAMAX Customer
Relations Department at 800-472-
5555.

CONTACTING PANAMAX

For product and warranty informa-
tion, dealer information, and other
general information contact
Customer Relations at:

Email:

[email protected]

Web:

www.panamax.com

Fax:

707-283-5901

Phone:

800-472-5555
or 707-283-5900,
7:30 a.m.- 5 p.m.PST

MAX

®

4400 PRODUCT SPECIFICATIONS

AC Surge Protection

Line Voltage……………......……………….120V, 50/60 Hz

Maximum Current Rating…….......................………….20A

UL 1449 Surge Suppression Rating…...................……330V

Protection Modes…………………….......…..L-N, L-G, N-G

Initial Clamping Level………........….200V Peak, 141V RMS

Response Time………...........................……………...<1ns

Joule Rating……………………............………1650 Joules

Peak Impulse Current……...........................………52,000A

EMI/RFI Noise Filtration……......…. 50dB (100KHz - 1 MHz)

Catastrophic Surge Circuit……......................………….YES

Thermal Fusing……...................……………………….YES

Over/Under Voltage Protection……....................………YES

Over-voltage shutoff threshold…………..............…147V ±8

Under-voltage shutoff threshold……..................……84V±6

DC Trigger

Connection………………….............……3.5mm mini-plug

Voltage and Polarity……..................5-30VDC, bi-directional

Current Requirement….......................…………...…>10mA

INS4400 REV. A 11/02

20A Circuit Breaker - will
automatically “open” when
the current load is greater
than 20 Amperes. When
this happens, the circuit
breaker can be manually
reset by simply pushing
the reset button, which
will have “popped” out.”

Always-On Outlets - Four
Always-On outlets provide
a constant power source.

Ground Lug -
Provides a common
grounding point for
equipment with
separate ground

Switched Outlets -
Four outlets controlled
by one of the two trig -
ger sources.

Voltage Sense Trigger
Input
- 3.5mm Mini-
Plug jack. Connect to a
remote trigger device
that provides 12VDC to
trigger a startup/ shut-
down sequence. This is
the second trigger that
will turn-on or turn-off
the switched outlets.

Turn-On Delay
Switch
- Provides
a 10-second
Turn-On delay
for the switched
outlets.

Switched Outlets Pushbutton -
one of two triggers that can
turn-on or turn-off the switched
outlets. Leave this switch in the
ON position if the DC trigger is
being used.

Ground OK LED -
(green) indicates that
the wall outlet is
properly grounded.

Unsafe Voltage - (red) when lit, indicates
that incoming voltage is unsafe and the
surge protector has disconnected the
power to protect your equipment.

Voltage Trigger LED -
(green) when lit, indicates
that the DC Trigger is
active (ON).

Switched Outlets LED -
Indicates that the
Switched Outlets
are on.

Always-on Convenience Outlet -

10 Ft. AC Power Cord -

1690 Corporate Circle, Petaluma, 94954 • Phone 707-283-5900 • Toll Free 800-472-5555 • Fax 707-283-5901 • www.panamax.com

Advertising