6

Time stamp resolution approx. 42 μs

Compliant with CAN specifications 2.0A and 2.0B

NXP PCA82C251 CAN transceiver

5-Volt and external power supply at the CAN connector
connectible by solder bridges, e.g. for external bus converter

Extended operating temperature range from -40 to 85 °C
(-40 to 185 °F)

Note: This manual describes the use of the PCAN-USB Hub
with Windows. You can find CAN drivers for Linux and the
corresponding application information on the provided DVD in
the directory branch Develop and on our website under
www.peak-system.com/linux.

1.2

System Requirements

A vacant USB port at the computer (USB 2.0 recommended)

Operating system Windows 7/Vista/XP (32/64-bit)
or Windows CE 6.x (x86 and ARMv4 processor support)
or Linux (32/64-bit)

Note: Do not use a USB extension cable to connect the PCAN-
USB Hub to the computer. The use of an extension cable does
not comply with the USB specification and can lead to
malfunction of the adapter.