Up to, Eco-power meters can be connected, Types and specifications – Panasonic KW4S User Manual

Page 5: Dimensions system diagram, Eco-power meter kw4s

Advertising
background image

Current

Changes

Dedicated protocol and MEWTOCOL

1 to 99 (Note)

Setting start

→ Protocol switch (dedicated or MEWTOCOL) →

Communication format change

Above content and communication procedure added.

Features added

Change

Communication protocol

Station number setting

Communication format setting

Instruction Manual

Only dedicated protocol

1 to 31

Setting start

Communication format change

Communication specifications

MEWTOCOL-COM commands

Types

Interface
Protocol
Isolation status
No. of connected units
Transmission distance
Transmission speed (Baud rate)

Transmission
data format

Communication method
Synchronous method
Terminating resistor

Conforming to RS485
Our method
Isolated with internal circuit
99 units*
1,200m
2,400, 4,800, 9,600, 19,200 bps (In each setting mode, settings can be made with front panel keys.)
7-bit/8-bit (In each setting mode, settings can be made with front panel keys.)
Not available/Odd/Even (In each setting mode, settings can be made with front panel keys.)
1 bit (Fix)
Half duplex
Start-stop synchronous method
Approx. 120

Ω (internal)

Note: You must use 1 to 31 when selecting the dedicated protocol (Eco-POWER METER data collection software: AKW4805).

• Please see the catalog (ARCT1E208E) for details on the Web Datalogger Unit.

• Please see the “FP series Programmable Controllers” catalog (ARCT1B230E) for details on the FP-e and FP0 PLC.

RD: Data area read command

WD: Data area write command

MD: Monitor data save and save reset command

MG: Monitor execute command

RT: Status read command

Data length
Parity
Stop bit

The Eco-POWER METER supports five commands.

*We recommend the SI-35 of Lineeye Co., Ltd., for the

RS485 converter on the PC side. (When using SI-35,
FP2-CB485 (for FP2-MCU), FP

Σ (COM3 and COM4) or

FP-e, the maximum number you can connect is 99. When
using with devices other than these, the maximum
number will be limited to 31.)

Up to

99

Eco-POWER METERs can be connected!

Installation is easy using a CT even
for the power lines of existing equipment
and machinery.

Shrink-wrapping
machine

CT

Power line

FP-e

Web
Datalogger
Unit

or

PC used for data

gathering and management

Types and Specifications

MODE

V

A

CHARGE

kWh

S E T

Ⅺ48

Ⅺ1.890

5.5

.217

5.5

.217

87.5

3.445

81.9

3.224

73

2.874

14.5

.571

1) Pin type

2) Screw terminal type

Dimensions

System Diagram

mm

inch

Eco-POWER METER KW4S

KW4S

Eco-POWER METER

Display: Integrated electrical

energy, Voltage, Current
and Electricity charge

(

Ⅺ44.5)

(

Ⅺ1.752)

(

Ⅺ44.5)

(

Ⅺ1.752)

Eco-POWER METER KW4S

01/2005