- 14 -

2K error messages

Message

Error description

AJ-HDP2000

ALARM LED

2048 or 1920

LED

REF IN SIGNAL UNMATCH SYSTEM
FREQUENCY

There is a mismatch in frame frequency between
the SYSTEM set value and REF IN.

OUT OF RANGE OF SYSTEM PHASE BETWEEN
REF AND INPUT

There is a large phase difference between the
input signal and REF IN.

(w/o OUTREF:

INPUT)

INPUT SIGNAL UNMATCH SYSTEM FREQUENCY There is a mismatch in frame frequency between

the SYSTEM set value and the input signal.

COMMUNICATION ERROR BETWEEN 2K
PROCESSOR AND HDD5

A communication failure occurs between
AJ-HDP2000 and AJ-HD3700B/A/H.
Check that the connection between AJ-HDP2000
and AJ-HD3700B/A/H is correct.

NO DUAL LINK CHA 2K INPUT

There is no input signal to Dual-Link IN Ach.
The format of the input signals to Dual-Link IN
Ach is outside the specifications.

NO DUAL LINK CHB 2K INPUT

There is no input signal to Dual-Link IN Bch.
The format of the input signals to Dual-Link IN
Bch is outside the specifications.

SUBSTANDARD TIMING DIFFERENCE IN DUAL
LINK 2K INPUT

The timing-phase difference of Dual-Link IN A/
Bch is outside the specifications (

R 100 ns)

CRC ERROR IN DUAL LINK CHA 2K INPUT

A CRC error occurs in signals on Dual-Link IN
Ach.

CRC ERROR IN DUAL LINK CHB 2K INPUT

A CRC error occurs in signals on Dual-Link IN
Bch.

UNMATCH H SAMPLE BETWEEN INPUT SIGNAL
AND SYSTEM

There is a mismatch in H SAMPLE between the
SYSTEM set value and the input signal.

DUAL LINK CHA 2K ASSIGNMENT IS CHB

On Dual-Link IN Ach, Bch is added to the
Channel Assignment information in PAYLOAD of
the input signals.

DUAL LINK CHB 2K ASSIGNMENT IS CHA

On Dual-Link IN Bch, Ach is added to the
Channel Assignment information in PAYLOAD of
the input signals.

DUAL LINK 2K INPUT FORMAT ASSIGNMENT IS
NOT PsF

On Dual-Link IN A/Bch, the input signal format of
the PAYLOAD information is not PsF.

D_LINK 2K INPUT COLOR SPACE ASSIGNMENT
UNMATCH SYSTEM

On Dual-Link IN A/Bch, color space information
of the input PAYLOAD signals does not match
the SYSTEM settings for the unit.

* If any warnings are generated while ERR/FMT or ERR are set in TC/CHR menu F13

(EX SUPER), “2K PROC ERROR” is displayed on SUPER of the Monitor OUT output.