Primera Technology Cyclone C-1000 User Manual

Page 40

Advertising
background image

36Interface Specifications

B. PARALLEL (CENTRONICS)

The parallel port is a standard 36-pin Centronics-type

connection. Its pin assignments are listed as following.

Pin

Direction

Definition

Pin

Direction

Definition

1

In

/STROBE

13

Out

SELECT

2

In

Data 1

14,15

NC

3

In

Data 2

16

-

Ground

4

In

Data 3

17

-

Ground

5

In

Data 4

18

NC

6

In

Data 5

19~30

-

Ground

7

In

Data 6

31

NC

8

In

Data 7

32

Out

/Fault

9

In

Data 8

33~36

-

NC

10

Out

/ACK

11

Out

BUSY

12

Out

PE

C. AUTO POLLING

Both the serial and parallel ports are active at the same time on

this printer, so data can be received on either one, however no

provision is made for port contention. If data is transmitted to

both ports simultaneously, it will cause the data in the received

buffer to be corrupted.

510172_r1.qxd 3/21/2001 6:25 PM Page 36

Advertising
This manual is related to the following products: