Control codes and escape sequences, Communications – Printek FormsMaster 8000 User Manual

Page 13

Advertising
background image

ANSI X3.64 Emulation

7

Control Codes and Escape Sequences

Grouped by Function

Communications

End of Text

ETX

If “ETX/ACK” is set to “On” in the serial interface setup menu, then receipt of an ETX causes the
printer to transmit an ACK to the host computer.

Since the ETX may be a legal value within an escape sequence, it is the user's responsibility to ensure
that an ETX used for data handshake is not sent within an escape sequence. The user must also ensure
that the maximum block size or the number of blocks sent at one time does not exceed the input buffer
size of the printer.

ETX/ACK handshake is available only with serial I/O.

Control code:

ETX

Hexadecimal:

03

Advertising