Panasonic PAN4570 User Manual

Page 12

Advertising
background image

CLASSIFICATION
Einstufung

No.
DS-Eval4570-2400

REV.

C

SUBJECT
Thema

EvalBoard PAN4570

PAGE
Seite

12 of 20

CUSTOMER’S CODE
EvalPAN4570

PANASONIC’S CODE

DATE
Datum

06.11.2006

European Technology Center

Panasonic Electronic Devices (EUROPE) GmbH

APPROVED

genehmigt

CHECKED

geprüft

DESIGNED

Erstellt

Connect the Ember™ Insight Adaptor to the SIF connector on the module carrierboard
with the grey ribbon cable supplied with the Insight Adaptor. Please make sure that pin1
of the plug connects to pin1 of the header.

5. Connect the Ember™ Insight Adaptor via a USB cable or crossover network cable

to the PC where EmberZNet™ is installed on.
Start xIDE.
Within the menue TOOLS\AutoDetectSIF check >Add SIF Pods< and click>Next<.
In the next window >Add new SIF Pod< click >Yes, search for new…<.
In the next window select your network adaptor and click >Next<.
In the next window select the detected SIF pod and click >Next<.
In the next window named >Configuration< click >Next<.
After the configuration the summary should be displayed:

Attempted to configure Ethernet Pod >address of Pod<
Found slave with no chip select.
Slave with no chip select is XAP2b

Within the menue TOOLS\Configure_SIF\SIF_configuration you can check for

the pods and slave configuration.

6.

On your pc create a new folder, for example C:\PAN4570

From the CD subfolder \software copy the following files to C:\PAN4570:

em2xx_load.exe
em250-rangetest.xpv
em250-rangetest.xdv
standalone-bootloader-em250.xpv
standalone-bootloader-em250.xdv

(Instead of em250-rangetest other applications could be selected)

Below an example for an upload after opening a DOS window on the pc

is shown (Ember

TM

Insight Desktop could be used instead).

The following DOS entries would start the programming of PAN4570 with
“Ember

TM

Range Test Application 2.0” including the embedded bootloader :

> cd c:\PAN4570

em2xx_load.exe –erase –btl c:\PAN4570\standalone-bootloader-em250
–Run c:\PAN4570\em250-rangetest

For details on using the em2xx_load.exe utility see also [9]