PRODUCT FEATURES

SAFETY DEVICE

A standard requirement for all vent-free room
heaters. This heater has a pilot with an Oxygen
Depletion Sensor(ODS) safety shutoff system.
The ODS/pilot shuts off the heater if there is
not enough fresh air.

PIEZO IGNITION SYSTEM

This heater is equipped with a piezo ignitor.
This system requires no matches, batteries, or
other sources to light heater.

THERMOSTATIC CONTROL ON
THERMOSTAT MODEL

These heaters have a control valve with a
thermostat sensing bulb. This results in the
greatest heater comfort and may result in
lower gas bills.

LOCAL CODES

Install and use heater with care. Follow all local
codes. In the absence of local codes, use the
latest edition of National Fuel Gas Code ANSZ223.1,
also known as NFPA 54*.
*Available from :
American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

1. Remove heater from carton.
2. Remove all protective packaging applied to
heater for shipment.
3. Check heater for any shipping damage. If heater
is damaged. promptly inform dealer where you
bought heater.

Figure1-Vent-Free Natural Gas Heater

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one
(1) ounce (30ml) of water for every 1,000 BTU’s
(.3KW’s) of gas input per hour.
Unvented room heaters are recommended as supple-
mental heat (a room) rather than a primary heat
source (an entire house). In most supplemental heat
applications, the water vapor does not create a
problem. In most applications, the water vapor en-
hances the low humidity atmosphere experienced
during cold weather.

The following steps will help insure that water vapor
does not become a problem.
1. Be sure the heater is sized properly for the

application, including ample combustion air and
circulation air.

2. If high humidity is experienced, a dehumidifier

may be used to help lower the water vapor con-
tent of the air.

3. Do not use an unvented room heater as the pri-

mary heat source.