SETTING menu

[7] INTELLIGENT SET

ATW WIDTH [1 to 5]
The color temperature range (1 to 5) used for
tracking ATW is set here.
With D5600K OFF, the range is set centering
on 200K or so; with D5600K ON, it is set
centering on 5600K or so.
The general color temperature tracking
ranges are listed in the table below.

ATW

WIDTH

D5600K OFF

D5600K ON

1

Approx.

000K to 000K

Approx.

500K to 7000K

2

Approx.

2500K to 5000K

Approx.

000K to 8000K

3

Approx.

200K to 8000K

Approx.

2500K to 9500K

4

Approx.

1900K to 10000K

Approx.

200K to 10500K

5

Approx.

1600K to 11000K

Approx.

1600K to 11000K

IRIS ON LOCK
[LOCK, MANUAL, PANEL]
The IRIS operation status when the intelligent
functions are locked is selected here.

LOCK:

The iris is held in the lock start
status.

MANUAL: The iris is switched to manual

operation.

PANEL:

Control that is exercised from
the camera controller switches
the iris operation between
IRIS AUTO and MANUAL.