Lx2206 e, Lx2206 – PowerDsine LX2206 User Manual

Page 6

Advertising
background image

LX2206 E

VALUATION

B

OARD

U

SER

G

UIDE

Microsemi

Integrated Products

11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570

Page 6

Copyright

© 2002

Rev. 1.1, 2006-11-17

LX2206

E

VAL

C

ONNECTIONS

Connections: The LX2206 Evaluation Board has
one power input and one power output connection.

F

UNCTION

P

IN

N

AME

V

OLTAGE

Input Power

PWR

5V +/- 0.65V

Input RTN

GND

0V

Battery +

BAT+

0V to 4.3V

Battery -

RTN

0V

Jumpers: The LX2206 Evaluation Board has two
position jumper blocks. The jumper can be moved to
select either a high logic level or low logic level. It is
also possible to remove the jumper and apply a
voltage directly to the center pin of the jumper block.

Hookup: The following is a demonstration scenario
that can be used to evaluate the LX2206.

1) Apply the single cell Lithium Ion or Lithium

polymer battery to the battery screw terminal
block. Be sure to connect the positive
terminal of the battery to the BAT+ terminal

and the Negative terminal to the RTN
terminal.

2) Apply a +5V power source to the PWR

terminal and the power supply return to the
GND terminal.

3) Move the SHUTDOWN jumper to the ON

position.

4) The POWER ATTACHED and CHARGING

LEDs should be lit when the battery is
charging and the POWER ATTACHED and
FULL LEDs should be lit when the battery is
fully charged.

5) Monitor the charge current into the battery

with a current probe.

6) Verify that the current changes levels

between approximately 92mA and 460mA
when the I PGM jumper is moved between
its two positions.

7) Verify that moving the SHUTDOWN battery

to the OFF position extinguishes the LEDs
and terminates the charge cycle.

8) The thermal lockout can be tested by

removing RT1 and replacing it with a
variable resistor to simulate the resistance of
RT1 under extreme hot and cold conditions.

Advertising