APPENDIX B

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC)

COMPLIANCE

Meets IEC standards 801.2, 801.4 and 801.5 (CE Mark)

Effective January 1996 the European Economic Community will

require that all electronic devices be tested and comply with all
applicable International standards relating to the product type and
category of use. Electromagetic Compatibility Directive 89/336/EEC
specifically addresses communication line surge protection devices,
since conformity to immunity standard EN50082-1:1992 is mandatory.
The EN50082-1:10992 standard incorporates International
Organization for Standardization (ISO) publications 801.2 and 801.4,
which describe Electrostatic Discharge and Electrical Fast Transient
requirements. ISO 801.5 describes Surge Immunity Requirements and
is expected to be adopted as a mandatory requirement under
EN50082-1 by the Technical Committee. in 1996. Any protector sold
into the international community must meet these standards. This
device has been tested* and found to comply with these standards as
evidenced by its CE mark.

*Note: All test results are for the Model 570/580 alone, not including the
standard 6” patch cable that is normally shipped with the unit.

APPENDIX A

SPECIFICATIONS

Environment: Category-5 Interfaces that utilize the RJ-45

connector, including RS-422, 423, 10Base-T, Token Ring, Fast

Ethernet, 100Base-T and ATM

Connectors: RJ-45 Female

Response Time: Clamped to 13 V after 0.1 µs

Characteristic Impedance: 100 Ohms

NEXT Loss: Model 570 - worst pair Better than -46 dB at 100 MHz;

Model 580 - worst pair Better than -43 dB at 100 MHz

Surge Clamp Voltage: Model 570 - 13 V max with 1 KV Input;

Model 580 - 15 V max with 2 KV Input

Surge Rating: IEC 801.5 Standard Level

DC Clamp Voltage: Common Mode to Gnd, each line

7.5 V @ 50 mA; Differential mode, per pair 8.1 V @ 50 mA

Insertion Loss: Less than 0.4 dB at 100 MHz (including connector)

Return Loss: Better than 14 dB

Group Delay: None, 1 MHz to 100 MHz

Series Resistance: Less than 400 milliohms

Grounding: External ground strap provides separate unit-ground to

chassis-ground contact

Dimensions: 2.25" x 1.69" x .75"

7

8

Class

1

1.0 kV

24 A

2

1.0 kV

24 A

3

2.0 kV

48 A

4

(n/a)
(n/a)

5

4.0 Kv

95 A

Wave

(1.2 x 50 µs)

Forms

(1.2 x 50 µs)

IEC 801-5 Threat Levels as a Function of Class

Sym. Lines Coupling Mode

Line-GND, Zs=42 Ohms

Figure B-1. IEC Threat Levels as a Function of Class.