PYLE Audio PP-5200 User Manual

Page 25

Advertising
background image

5 - 3

points to the connector area of the printer. The OFF direction
points to the power switch. The functions of each position may
evolve with the revisions of the firmware. The information below
applies to the latest version to the date of print of this manual.

This 8 position DIP switch works as following:

Switch

position

ON

OFF

1
2

RS232 baud rate definition or Parallel interface

definition (ref. separate table below)

3

Even parity

None parity

4

XON handshaking

Hardware handshaking

5

Busy on “buffer full”

Busy on “off line”

6

Immediate cut

Protective cut

7

CR code effective

CR code ineffective

8

Factory internal setting

Application standard mode

Effect of positions 1 & 2 on baud rate is defined as in table

below with parity check set according to position 3, number of
data bits always set to 8, and stop bit set to 1. When the parallel
interface is used, please set both positions to ON.
SW Pos. 1 ON

OFF

ON

OFF

SW Pos. 2 ON

ON

OFF

OFF

Baud rate
or Interface

38400 bps /
(Parallel)

4800 bps

9600 bps

19200 bps

Switch position 3 defines the parity check regulation in

serial interface. In Aura, it is selectable between even and none.

Switch position 4 defines the handshaking method in serial

interface. When it is set to ON, the printer transmits an “XOFF”
for busy and sends an “XON” for not busy. When it is set to OFF,
the printer signifies the busy status over hardware signals that can
be detected by the host as “DSR” or “CTS”. When parallel
interface is used, both switch positions 3 and 4 should be set to
OFF.

Advertising