Measurement, 1 horizontal angle measurement (right) – Pentax ETH-310 User Manual

Page 34

Advertising
background image

34

5. Measurement

5.1 Horizontal angle measurement (right)

Level the instrument, and after power on set the vertical angle 0 point.
Sight the first object using the horizontal clamp and tangent screw as
well as the telescope clamp and tangent screw.
Press [0SET] twice to set the horizontal angle to 0°,00’,00”
Sight the second object using the horizontal clamp and tangent screw
as well as the telescope clamp and tangent screw.
Read the displayed value (

α).

First Object: Zero Setting (0 °00’ 00”)

Second Object (34 °47’ 20”)

Horizontal Angle (

α) = 34 °47’ 20”

1

2

4

5

3

First object

Second object

Advertising