Specifications, Single inverter split, Single split – Panasonic AC Robot 2006/2007 User Manual

Page 19: Rating conditions

Advertising
background image

Specifications

• Power plugs are not supplied with the unit.
• Electrical work must be installed by a licensed electricians. Be sure to use the correct rating

of the power plug and mains circuit for the model to be installed.

• Please read the Installation Instructions carefully before installing the unit, and read the

Operating Instructions before using.

Power

Supply

27

°C DB/19°C WB

20

°C DB

35

°C DB

7

°C DB/6°C WB

Cooling

Inside air temperature

Outside air temperature

Heating

Rating Conditions

Single Inverter Split

Btu/h

kW

L/h

Outside

A

kW

W/W

kg

mm

Inside (Hi/Lo) Outside (Hi/Lo)

Cooling Capacity

Heating Capacity

Air Flow Dehumid

Running

Current

Power

Input

EER

COP

Sound Pressure

Level

*

1

dB (A)

Sound Power

Level dB (A) Net Weight

Maximum

Pipe

Length

*

2

m

Dimensions

Height x Width x Depth

Model No.

(240V)

L/s

*

1

Sound Pressure Level is measured according to JIS C 9612.

*

2

Additional Gas might be required for some models.

Star

Rating

Pa(mmAq)

External

Static

Pressure

CS-XE9EKE
(CU-XE9EKE)

2.60

(0.60~3.00)

3.60

(0.60~6.10)

8,870

(2,050~10,200)

12,300

(2,050~20,800)

13

(37)

305 x 870 x 229

(540 x 780 x 289)

1.6

15

4.56

4.44

39 / 26

40 / 27

46 / —

47 / —

2.7

3.7

0.57

(0.12~0.70)

0.81

(0.115~1.64)

59

60

177

195

6.0

6.0

Indoor

CS-XE12EKE
(CU-XE12EKE)

3.50

(0.60~4.00)

4.80

(0.60~6.70)

11,900

(2,050~13,600)

16,400

(2,050~22,800)

13

(37)

305 x 870 x 229

(540 x 780 x 289)

2.0

15

3.98

3.93

42 / 29

42 / 33

48 / —

50 / —

61

63

4.0

5.4

0.88

(0.12~1.10)

1.22

(0.115~1.84)

198

212

6.0

6.0

Indoor

Cooling

Heating

EER: Cooling Efficiency

COP: Heating Efficiency

( ): Outdoor Unit

Single Split

*

1

Sound Pressure Level is measured according to JIS C 9612.

*

2

Additional Gas might be required for some models.

Power

Supply

W/W

Maximum

Pipe

Length

*

2

Model No.

CS-W7DKR
(CU-W7DKR)

CS-W9DKR
(CU-W9DKR)

CS-W12EKR
(CU-W12EKR)

CS-W18DKR
(CU-W18DKR)

CS-W24EKR
(CU-W24EKR)

7,840

9,380

12,300

18,100

24,000

2.30

2.75

3.60

5.30

7.03

L/h

1.5

1.6

2.1

2.9

4.0

Outside

kg

9

(26)

9

(29)

8

(35)

11.0

(56.0)

11.0

(63.0)

mm

280 x 799 x 183

(510 x 650 x 230)

280 x 799 x 183

(510 x 650 x 230)

280 x 799 x 183

(540 x 780 x 289)

275 x 998 x 230

(750 x 875 x 345)

275 x 998 x 230

(750 x 875 x 345)

8,350

10,400

13,300

19,600

26,600

2.45

3.05

3.90

5.75

7.80

Cooling Capacity

Heating Capacity

Air Flow

Dehumid Running

Current

Power

Input

EER

COP

Sound Pressure

Level

*

1

dB (A)

Sound Power

Level dB (A) Net Weight

Dimensions

Height x Width x Depth

L/s

143

162

A

3.2

3.0

3.8

3.8

5.0

4.9

7.8

7.8

11.1

11.7

kW

0.72

0.685

0.875

0.865

1.1

1.09

1.81

1.80

2.37

2.46

3.19

3.58

3.14

3.53

3.27

3.58

2.93

3.19

2.97

3.17

Inside (Hi/Lo)

34/26

36/26

36/26

39/26

41/29

42/29

43/38

42/38

47/41

46/41

Outside (Hi/Lo)

47/—

49/—

49/—

50/—

50/—

50/—

50/—

51/—

53/—

54/—

132

152

63

64

62

64

64

65

65

66

66

67

Star

Rating

(240V)

m

10

10

15

25

25

Indoor

Indoor

Indoor

Indoor

Indoor

Cooling

Heating

EER: Cooling Efficiency

COP: Heating Efficiency

( ): Outdoor Unit

178

182

255

267

290

303

5.0

6.0

4.5

5.5

4.5

4.5

4.0

3.5

3.5

3.0

Btu/h

kW

2.60

(0.80~3.00)

3.60

(0.80~5.00)

8,870

(2,730~10,200)

12,300

(2,730~17,100)

9

(37)

280 x 799 x 183

(540 x 780 x 289)

1.6

15

4.33

4.26

39 / 26

40 / 27

46 / —

47 / —

2.8

3.8

0.60

(0.175~0.78)

0.845

(0.165~1.36)

59

60

160

175

6.0

6.0

Outdoor

CS-E9FKR
(CU-E9FKR)

3.50

(0.80~4.00)

4.90

(0.80~6.70)

11,900

(2,730~13,600)

16,700

(2,730~22,800)

9

(37)

280 x 799 x 183

(540 x 780 x 289)

2.0

15

3.63

3.89

42 / 29

42 / 33

48 / —

50 / —

61

63

4.3

5.6

0.965

(0.185~1.20)

1.26

(0.175~1.89)

178

187

6.0

5.5

Outdoor

CS-E12FKR
(CU-E12FKR)

4.40

(0.90~5.00)

5.50

(0.90~7.10)

15,000

(3,070~17,100)

18,800

(3,070~24,200)

9

(48)

280 x 799 x 183

(750 x 875 x 345)

2.4

15

3.21

3.50

43 / 32

43 / 35

46 / —

46 / —

59

59

6.2

7.0

4.5

4.5

1.37

(0.215~1.60)

1.57

(0.245~2.25)

183

197

Outdoor

CS-E15FKR
(CU-E15FKR)

5.30

(0.90~6.00)

6.60

(0.90~8.00)

18,100

(3,070~20,500)

22,500

(3,070~27,300)

11

(49)

275 x 998 x 230

(750 x 875 x 345)

2.9

20

3.21

3.69

44 / 37

44 / 37

47 / —

47 / —

60

60

7.3

7.9

4.5

5.0

1.65

(0.215~2.05)

1.79

(0.245~2.65)

253

278

Outdoor

CS-E18FKR
(CU-E18FKR)

6.30

(0.90~7.10)

7.20

(0.90~8.50)

21,500

(3,070~24,200)

24,600

(3,070~29,000)

11

(51)

275 x 998 x 230

(750 x 875 x 345)

3.5

20

3.06

3.60

45 / 37

45 / 37

48 / —

49 / —

61

62

9.0

8.8

4.0

4.5

2.06

(0.215~2.40)

2.00

(0.245~2.70)

270

288

Outdoor

CS-E21FKR
(CU-E21FKR)

7.20

(0.90~8.10)

8.60

(0.90~9.90)

24,600

(3,070~27,600)

29,300

(3,070~33,800)

12

(72)

275 x 998 x 230

(795 x 900 x 320)

4.2

30

Outdoor

3.13

3.43

47 / 38

47 / 38

52 / —

52 / —

66

66

10.3

11.1

4.0

4.0

2.30

(0.35~2.70)

2.51

(0.36~3.20)

282

305

CS-E24FKR
(CU-E24FKR)

27,600

(3,070~29,300)

32,700

(3,070~37,500)

12

(72)

275 x 998 x 230

(795 x 900 x 320)

4.8

30

Outdoor

2.98

2.95

49 / 38

48 / 38

53 / —

53 / —

67

67

12.0

14.4

3.5

3.0

2.72

(0.35~2.95)

3.25

(0.36~3.79)

295

312

8.10

(0.90~8.60)

9.60

(0.90~11.00)

CS-E28FKR
(CU-E28FKR)

A

10

10

10

10

10

15

20

20

20

A

10

10

10

10

20

19

Advertising