PORT-A-COOL® Hazardous Location Units

*

APPENDIX A

A-1

Port-A-Cool®

TEMPERATURE OUTPUT CHARACTERISTICS

10% TO 25% RELATIVE HUMIDITY

DRY BULB

Temp. °C

Temp. °F

32.2 90
35.0 95

37.8 100
40.6 105
43.3 110
46.1 115

TEMP. °F

Difference

Drop

65 46.8
65 46.8
66 47.5
67 48.2
68 49.0
67 48.2

OUTPUT TEMP.

°C °F

6.1 43
8.9 48

11.1 52
13.9 57

16.1 61

19.4 67

DRY BULB

Temp. °C

Temp. °F

32.2 90
35.0 95

37.8 100
40.6 105
43.3 110
46.1 115

TEMP. °F

Difference

Drop

55 39.6
56 40.3
57 41.0
57 41.0
58 41.8
59 42.5

OUTPUT TEMP.

°C °F

10.0 50
12.8 55
15.0 59
17.8 64

20.0 68

22.8 73

DRY BULB

Temp. °C

Temp. °F

32.2 90
35.0 95

37.8 100
40.6 105
43.3 110
46.1 115

TEMP. °F

Difference

Drop

47 33.8
47 33.8
48 34.6
49 35.3
49 35.3
51 36.7

OUTPUT TEMP.

°C °F

13.3 56
16.1 61
18.3 65
21.1 70

23.9 75

25.6 78

DRY BULB

Temp. °C

Temp. °F

32.2 90
35.0 95

37.8 100
40.6 105
43.3 110
46.1 115

TEMP. °F

Difference

Drop

41 29.5
43 31.0
44 31.7
44 31.7
44 31.7
45 32.4

OUTPUT TEMP.

°C °F

15.6 60
17.8 64
20.0 68
22.8 73

25.6 78

28.3 83

WET BULB TEMPERATURE

DRY BULB TEMPERATURE

TEMPERATURE DIFFERENCE

TEMPERATURE DROP

OUTPUT TEMPERATURE

Wet Bulb Temperature @ Current Humidity Level
Current Ambient Air Temperature
Dry Bulb Temp Minus Wet Bulb Temp
Temperature Difference Multiplied by 72%
Dry Bulb Temperature Minus Temperature Drop

10% RH

15% RH

20% RH

25% RH