Do I Have the Correct Power Supply?

The following ac power supplies are available. Make sure that you have the correct one
for your housing and application.

NOTE:

The 120 Vac power supply has a label to warn you to connect the supply only to a
100–120 Vac power source.

Name/Feature
Number

Wattage/Volts

Fits in This
Housing

Keyed?

For
International
Use?

120 Vac Power
Supply
(Feature No.
9005-F1-020)

60 watts,
100–120 Vac

5-slot only

No

No

Universal
Power Supply
(Feature No.
9007-F1-040)

70 watts,
100–240 Vac

Access Carrier
only

Yes (

see figure

on page 3)

Yes

Technical Specifications for 120 Vac Power Supply in 5-Slot Housing

Specification

Criteria

Rated Nominal Voltage

100–120 Vac, 50/60 Hz

Operating Voltage Range

85–132 Vac, 50/60 Hz

Rated Current

1.5 Amps

Power Consumption (typical)

1 power supply installed

120 Vac 60 Hz 1.03 amps 60 watts

100 Vac 50 Hz 1.15 amps 60 watts

Result: 207 Btu per hour

2 power supplies installed

p

120 Vac 60 Hz 1.13 amps 64.5 watts

100 Vac 50 Hz 1.25 amps 64.5 watts

Result: 221 Btu per hour