Airflow direction control – Panasonic CS-A9CKPG User Manual
Page 30
1. Vertical Airflow Direction
•
Thelouver swings up and down as shown above.
•
The louver does not swing when the Indoor Fan stops
during operation at the upper limit.
Heating Mode
•
When the intake air temp. reaches 38°C (100.4°F), the
louver is changed from upper to lower limit. When the
intakeair te
mp falls to 35°C (95°F), thelouve
r is
changed from lower to upper limit.
2. Horizontal Airflow Direction
•
The louver can be selected between 14° - 36° (as
shown above) when pressing Manual Airflow Direction
Selection Button.
•
The louver can be selected between 0° - 61° (as shown
above)
when
pressing
Manual
Airflow
Direction
Selection Button.
8.9.
Airflow Direction Control
Cooling, Ion and Soft Dry Mode
•
The left and right airflow direction louvers can be adjusted manually.
30
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G